DP-8020E/8020P/8016P
4.1.7.F8 Mode: Service Adjustment
Set the machine to Service Mode, and press "8" key on the Keypad.
?
Press the "START" key.
?
Enter the desired code number, or press ?V?, ?/\? arrow keys.
?
If you wish to select another code number, scroll the menu with the arrow keys.
?
Press the "SET" key.
?
Enter the desired function code number, and press ?SET? key.
?
When the ?CLEAR? key is pressed, the selected code input will not be accepted.
?
Press ?STOP? key, then press ?FUNCTION?, and ?CLEAR? keys simultaneously to exit the service mode.
?
Reboot the machine after setting the parameter(s) to activate the setting(s).
F8 Mode
No.ItemRemarks
00Exp. Lamp ReplacementWhen replacing the exposure lamp.
Procedure:
a) Press the Start key to move the exposure lamp to
the position (approx. 250 mm from the optics
home position) where it can be replaced.
b) To return the optical system to the home position,
press the CLEAR key.*
01-05 Not Used
06Error Log Print/Viewa) Each time the arrow key is pressed, the machine
errors, or paper jam codes stored in memory are
displayed, beginning with the oldest code.
Note:
Only the 30 most recent codes are displayed.
07Error Log Cleara) Press the Reset key.
A Message "Error code can be cleared with the
Start key" is displayed on the LCD.*
b) Press the Start key.
08(Factory use only)Lock operation for Scanner Unit.
09Toner Density AdjustmentAdjustment operation of Toner Density.
10Drum Charge AdjustmentAdjustment operation of Drum Charge.
11Not Used
12Org.size Sensor Adj.Adjust the slice level for the original size detection
(Not Used)sensors automatically. Execute this mode by closing
the platen cover.
13Black Density ReferenceAdjustment operation of Black Density sensor.
(Not Used)
14OPC Counter ResetProceed when OPC is replaced.
15-17 Not Used
18LSU PWM PatternPrint out the Test Pattern.
Proceed when the LSU is replaced.
165
Ver. 1.0OCT 2006 |