2. Flange Back AdjustmentAdjusting method:
(Using Minipattern Box)1) Install the minipattern box so that the distance between it and
The inner focus lens flange back adjustment is carried outthe front of the lens of the camera is less than 3cm.
automatically. In whichever case, the focus will be de2) Make the height of the minipaviated duringttern box and the camcorder equal.
auto focusing/manual focusing.3) Check that the output voltage of the regulated power supply is
ModeSTILL11.29 ? 0.01Vdc.
4) Select page: 0, address: 01, and set data: 01.
SubjectSiemens star chart with ND filter for5) Select page: 5, address: F1, and set data: FF.
the minipattern box (Note1)
6) Check that the center of the Siemens star chart and center of
Measurement PointCheck operation on TV monitorthe exposure screen coincide.
Measuring Instrument7) Check that the data of page: F, address: 14 to 25 is the initial
Adjustment PageFvalue (See table below).
Adjustment Address14 to 25AddressDataAddressDataAddressData
14101A002020
Note 1:Dark Siemens star chart.15001B002120
Note 2:Check that the data of page: 6, address: 02 is O00�. If not, turn the
power of the unit OFF/ON.16101C002200
17011D002340
Preparations before adjustments:18111E00240A
The minipattern box is installed as shown in the following figure.19001F002500
Note: The attachment lenses are not used.
8) Select page: 6, address: 01, set data: 13, and press the PAUSE
Below 3 cmbutton of the adjustment remote commander.
9) Select page: 6, address: 01, set data: 27, and press the PAUSE
Minipattern boxbutton.
(The adjustment data will be automatically input to page: F,
Cameraaddresses: 14 to 25.)
10) Select page: 6, address: 02, and check that the data is changed
to O01�.Table
Processing after Completing Adjustments:Regulated power supply
11.29 ? 0.01Vdc1) Select page: 6, address: 01, set data: 00, and press the PAUSE
Output current more than 3.5Abutton.
2) Select page: 5, address: F1, and set data: 00.
3) Perform OFlange Back Check�.
Red (+)
Black (�)
Yellow (SENS +)
White (SENS �)Need not connected
Black (GND)
Fig.5-1-11.
5-20 |