1-1-4. Using Method of SEUS2. Operation
YPage change
The application for adjustment (SEUS) is used to change the coef-To change the page, click [Page] on the SEUS screen and enter
ficient for calculating the signal processing or EVR data. the page to be changed. The SEUSThe page is displayed in hexadecimal
performs two-way communication between PC and set throughnotation.
the USB terminal. The two-way communication result data can be
written to the nonvolatile memory.Y Address change
To change the address,[Address] click on the SEUS screen and
1. Connectionenter the address to be changed. The address is displayed in
1) Connect the HASP key to the USB terminal of the PC.hexadecimal notation.
2) Connect the PC and set with the USB cable.
3) Confirm that the set starts in the USB mode.Y Data change
4) Start the SEUS on the PC.To change the data, click [Set] on the SEUS screen and enter
5) Clic[Connect]k on the SEUS screen. If the connection is northe data. -The data is displayed in hexadecimal notation.
mal, the SEUS screen will be as shown in Fig. 6-1-7, indicat-This operation does not write the data to the nonvolatile memory.
ing the Oconnected� state.
Note:The SEUS will go in Odisconnect" state, if the set isYData saving
To write the all changed data to the nonvolatile memory, click
turned off (for instance, by resetting the set). In such a
[Save] on the SEUS screen and wait for more than 3 sec.
case, click [Connect] on the SEUS screen to restore
the Oconnected� state.
Y Data reading
The data displayed on the SEUS screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click
[Read] on the SEUS screen and update the displayed data.
1-1-5. Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking [Page Edit] on the SEUS screen be-
fore starting the adjustment.
Saving Method:
1) Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click [Page], and enter the page number to be saved.
3) Click [Page] to read the data to be saved from the camera.
4) Click [File] and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3) Click [File] and load the data from PC.
4) Clic[Write]k on the SEUS PAGE EDIT screen.
Fig. 6-1-7
5) Clic[Close]k to close the SEUS PAGE EDIT screen.
6) Click [Save] on the SEUS screen.
7) Wait for more than 3 sec.
8) Select page: 80, address: 30, and check that the data is O00�.
9) Select page: 00, address: 01 and set data: 00.
6-7 |