DV-C503
Description
FLCauses if with a DVDCauses if with a CDOperation of the Unit
of Error
ID can not read
71An ID could not be read for 1 second or more.Stop
during tracing
Subcode check No frame could be read for 3
72Stop
failure during seconds or more.
playback
ID can not read at An ID could not be read within 1 second after the
73Opens (ID readout failure)
the startupAFB adjustment had been finished.
No subcode could be read within 3
Subcode check Opens (Subcode readout
74seconds after AFB adjustment had
failure during startupfailure).
been finished.
Timeout for reading
TOC readout took 30 seconds or
81TOC of the Stop
more.
mechanism
controller
Timeout for reading Reading TOC of the system
82TOC of the system Stop
controller took 30 seconds or more.
controller
Communication A command could not be issued to DSP because
A1timeout of DSP Command Busy (XCBUSY) was in force No operation
command(XCBUSY = L) for a specified time (about 200
mS).
Command Busy (XCBUSY) was in force for a
Communication specified time (about 200 mS) before and after a
A2timeout for reading coefficient read command was issued to DSP, or No operation
DSP coefficient
the address echo-back after command issuance
did not match the setup address.
Communication Command Busy (XCBUSY) was in force for a
A3timeout for writing specified time (about 1024 mS) before and after No operation
DSP coefficientthe coefficient write command was issued to
DSP.
Communication Command Busy (XCBUSY) was in force for 200
timeout for mS during continuous coefficient writing, or
A4No operation
continuously writing before and after a continuous write command
DSP coefficientwas issued to DSP.
In the tracing state during the backup sequence, codes could not be read for 1
Timeout error for
B1second or more. In the backup sequence, tracking ON sequence of the servo DSP Stops
backup
could not be completed even if more than 500 mS after the tracking ON command
was issued.
Retry error for
B2Tracing impossible after retring the tracking ON for 3 times in the backup sequence.Stops
backup
During tracing, runaway was detected after three iterations of backup operations for
B3 Retry error for traceStops
detecting runaway.
Stops (the mechanical
Detection of tracking During playback, the overcurrent detection port was at L for 300 ms or more
C3controller operates
overcurrentcontinuously.
independently).
Turns off the power
Short-circuit test While the power was on, the overcurrent detection port was at L for 40 ms or more instantly (No indication on
(C5)
corresponding errorcontinuously.the FL display and no
writing to flash memory)
Violation against
E3Stops
digital copy guard
The tray switch that had been Open mode was forcibly changed to a mode other than
F5 Tray being pushedCloses
Open by an external force.
Reverses the loading
Loading, unloading or clamping could not be completed within a specified time (about
F8 Loading timeoutdirection. It timeout is
5 seconds).
repeated upon retry, the
unit stops.
The following error occured eight times. (1) Focus ON sequence could not be Stops wherever possible
FC Focuscompleted even if more than two seconds after the focus ON command (to the then opens (stops in the
servo DSP) was sent. (2) Focus IN sequence was finished, actually focus IN was not case of side B).
completed.
57 |