ELECTRICAL CONNECTIONS
Important
Any electrical work required to install
this cooker should be carried out by a
qualified electrician or competent person, in
accordance with the current regulations.
THIS COOKER MUST BE EARTHED
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to a
240V, 50Hz electrical supply.
To connect to the electricity supply, use cable
type H05 RR-F.
NOTE: The earth wire should be about 2 cm
Before connection, make sure the electricitylonger than the live and neutral wires.
supply voltage is the same as that indicated on
the rating plate.Before connecting check that:
The cooker is supplied without supply cable. A 3
" The fuse and household electrical installation
core flexible supply cord must be fitted, incan carry the absorbed current of the
accordance with the specification given in the
appliance (see rating plate);
table no.1.
" The cooker connection outlet or the cooker
The electrical connection should be made using
control switch is easily accessible when the
a double pole isolating switch (cooker control
appliance is installed.
switch) with at least 3mm contavt separation in
all poles. The cable must have conductors ofHow to proceed?
sufficiently high cross-sectional area to prevent
overheating or deterioration." Unscrew and remove the protective cover at
the back of the appliance;
The switch should be sited within 2m of the
" Connect the power cable to the terminal
cooker and be easily accessible at all times.block of the cooker according to the table
no.1;
The yellow-green earth wire must not to be
" Secure by means of cable clamp;
interrupted by the switch.
" Make sure that the connection to the terminal
block is matching the supply system, see
Ensure that the cooker supply cabletable no.1;
does not come into contact with surfaces" Refit and screw the protective cover on the
with temperatures higher than 50 °C.back of the appliance.
Table no.1
Connection typeSingle phase (UK)
1 2 3 4 5
Cable connection to the
terminal block
L1NPE
Mains Voltage240 V
Voltage of heating
240 V
elements
Fuse capacity32 A
2
Cable section3x6 mm