11. MAX GAIN Adjustment12. Auto White Balance Standard Data Input
Setting the minimum illumination.
SubjectClear chart
If it is not consistent, the image level required for taking subjects in
(Color bar standard picture frame)
low illuminance will not be produced (dark).
Adjustment PageF
SubjectClear chartAdjustment Address70 to 73
(Color bar standard picture frame)
Note 1:Perform OColor Reproduction Adjustment� before this
Measurement PointDDS display of TV monitor
adjustment.
Measuring Instrument (Note 1)
Note 2:Check that the data of page: 2, address: 02 is 00. If not,
Adjustment PageF
turn the power of the unit OFF/ON.
Adjustment Address31
Specified ValueA8 to FF
Adjusting method:
Note 1:The right two digits of the display data at the right bottom
1) Select page: 0, address: 01, and set data: 01.
side of TV monitor is the object data.2) Wait for 2 seconds.
00 XX XX
3) Select page: 2, address: 01, and set data: 11, and press the PAUSE
n Object data
button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 0D, and press the PAUSE
Adjusting method:
button of the adjusting remote commander.
1) Select page: 0, address: 01, and set data: 01.(When the standard data is take in, the data will be automatically
2) Select page: D, address: 11, and set data: 02, and press the PAUSE
input to page: F, address: 70 to 73.)2. ADJUSTMENT
button of the adjusting remote commander.
5) Select page: 2, address: 02, and check that the data is O01�.
3) Select of page: 0, address: 03, and set data: 01.6) Perform OAuto White Balance Adjustment�.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 56, and set data: 40.Processing after Completing Adjustments
6) Select page: 2, address: 01, set data: 19, and press the PAUSE
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
7) Select page: F, address: 31, set data: 08, and pr2) Select page: 0, address: 01, and set data: 00.ess the PAUSE
button of the adjusting remote commander.
8) Check that the DDS display data (Note 1) lies within the specified
value.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 00.
5) Select page: 2, address: 56, and set data: 00.
6) Select page: 0, address: 03, and set data: 00.
FCB-IX47/47P
2-21 (E)
FCB-IX470/470P |