FR-N3X
ADJUSTMENT PROCEDURES-2
MD ADJUSTMENT
4. Test mode
4-1. How to test mode to enter
(1) Connect the power supply cord in the wall socket.
(2) Turn on power by Pressing Press STANDBY/ON.
(3) Select the MD by pressing the CD/MD.
FL display ---"No Disc "
(4) While hold down MODE/YES button, press DISPLAY.
FL display --- For example "020328EXX-a "
(5) Press STANDBY/ON.
When the unit is not a clock display at this time, continue pushing STANDBY/ONFL Display
again and set the state of a clock display.
FL display --- "--:-- " TEMP ADJUST
(6) While hold down MODE/YES, press the MD EJECT.
4-2. How to cancel test mode
Disconnect the power supply cord from the wall socket.
4-3. Cautions on Test Mode
(1) Don't use the disk which you must not eliminate in test mode.
(2) Push the EJECT button after pressing EDIT/CLEAR/NO, when taking out disk in test mode.
4-4. Basic operation in Test Mode
Select the test mode
adjustment
Returns to a front step
Cancel
Progresses to the following step.
Go to next step
4-5. Select the test Mode
EDIT/CLEAR
JOG PUSH
FL Display/NO
CancelGo to test select mode.
TEMP ADJUSTRecord of the fiducial point of temperature data.
LDPWR ADJUSTLaser power adjustment
LDPWR CHECKCheck the laser power
LOAD CHECKCheck the loading operation.
SLEVEL CHECKCheck the lens of the pickup.
EFBAL ADJUSTTraverse (EF balance) adjustment
FBIAS ADJUSTFocus bias adjustment
FBIAS CHECKCheck the focus bias adjustment
CPLAY MODEContinuous play back mode
CREC MODEContinuous recoding mode
EEP MODEData memorized in non-volatile memory
POINT ADJUSTSetting the access point on CREC and CPLAY mode. |