TROUBLESHOOTING
Before calling for repair, check the symptoms below for possible remedies, since the problem may
not be a malfunction of the unit.
SYMPTOMREMEDY (not a malfunction)
The remote control does notYHave the batteries depleted?
w orkY Are the batteries inserted correctly?
Y Is a fluorescent lighting in the room flickering due to service
life? (Refer to E-3)
Odors and smoke cannot be re-Y Are the filters heavily soiled? (Refer to E-13)
moved easily
The Clean sign lights greenY Is the opening of the dust sensor blocked or clogged?
even when the air is dirtyYWas the air already dirty when the power plug was inserted
into the wall outlet? (Refer to E-4)
The Clean sign lights orange orY The sensitivity of the sensor becomes unstable when the
red even when the air is cleanopening of the dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-12)
The cluster ion lamp remainsY During the Clean mode (or Refresh mode), the cluster ion lamp
green (blue) and does notcolour will not change.
change
A sound isClick, clickY This is the sound that is emitted when the unit is in t h e
heard from theRefresh mode.
unitIf the sound is irritating, switch the unit to the Clean mode.
Y This is the sound that is emitted when the unit is generating
cluster ions.
Tick, tick, tick
If the sound is irritating, such as when sleeping, etc., set the
Cluster ion mode to OFF.
The discharged air smellsY The ozone generated by the cluster ion generator may have
an odor. However, the density of ozone generated is very little
and is harmless to the human body. Furthermore, the ozone
decomposes quickly so it does not accumulate in the room.
The unit does not operate evenY Is the unit installed in a location that is difficult for the sensors
when smoking cigarettesto detect cigarette smoke?
Y Are the odour and dust or dust sensor openings blocked or
clogged? (In this case, clean the openings.)
(Refer to E-12)
The applicable floor surface area is the surface area for
when operating the unit in Max fan level.
(According to Japan Electrical ManufacturersO Association
SPECIFICATIONS
JEM1467)
Power supply220V-240V 50Hz
Fan level adjustmentMaxHighMedianSilent
Fan level
Rated power39W21W10W4W
operation
3333
Fan level240m/hour 180m/hour 117m/hour 30m/hour
Applicable floor surface~31m2
Cord length2.5m
Dimensions415mm(W)X197mm(D)X572mm(H)(W/ stand)
Weight6.6kg
About the reduction of standby power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product
consumes about 0.8W of standby power.
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when
not using the unit