5.3 EMERGENCY DISPLAY
Example (in case of the error number E01):
Whenever some abnormal signal is input to the mechacon CPU,
an error number (E01, as an example) is displayed in the elec-
E01 E01
tronic view finder. In every error status, such the message as
UNIT INREMOVE AND
shown below alternately appear over and over. SAFEGUARD MODE REATTACH BATTERY
? In an emergency mode, all operations except turning on/off the
POWER switch are ineffectual.
E. VFSymptomMode when observed
E07 Short circuit of capstan MDAPower ON
E06 CAPSTAN FG input absentCAPSTAN rotation
E04 DRUM FG input absentDRUM rotation
E03 SUPPLY REEL FG input absentREC, PLAY, SEARCH, FF/REW
E02 Mode control motor rotates for more than 7.5 sec UNLOADING without shift to nextUNLOADING
mode.
E01 Mode control motor rotates for more than 7.5 sec LOADING without shift to next mode.LOADING
E00 Overtime the programming transactionREC, PLAY
(NTSC)
1-24 (No.YF073) |