SERVICE SAFETY PRECAUTIONS
1. Replacing the fuse2. Safety check out
This symbol located near the fuse(Only U. S. A. model)
indicates that the fuse used is fastAfter correcting the original service problem, perform the
operating type. For continued protection against fire hazard,following safety check before releasing the set to the customer.
replace with same type fuse. For fuse rating refer to the Connect the insulating-resistance tester between the plug of
marking adjacent to the symbol.power supply cord and screw on the back panel.
Specifications: 3.3M ohm +/- 10% at 500 V.
Ce symbol indique le fusible utlise est a rapide.
Pour une protection permanente, n'untiliser que fusibles de
meme type. Ce darnier est la qu le present symbol est appse.
Circuit No. Part No.Description
F901252159 2A-UL/T-237 <D>
NOTE: <D>: 120 V model only
3. To initialize the unit
1. Press the standby button.
2. Press and hold down the STANDBY/ON, them press the
LATE NIGHT butoon at remoter controller.
3. After "CLEAR" is dislpayed, and initialized the unit.
4. Test mode
1. Press the standby button.
2. Press and hold down the STANDBY/ON, them press the
CHANNEL butoon.
3. Press the LEVEL/DISTANCE button and get the test mode
displayed "TEST-1-00".
EX) "TEST-1-00~01" is used the fan control operation. |