HCD-EP50
SECTION 4SECTION 5
MECHANICAL ADJUSTMENTSELECTRICAL ADJUSTMENTS
PRECAUTIONPRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened1. Setting
swab :MEGA BASS switch : OFF
record/playback headpinch roller
erase headrubber belts
TAPE DECK SECTION0 dB=0.775 V
capstanidlers
2. Demagnetize the record/playback head with a head demagne-Test tape
tizer. (Do not bring the head magnetizer close to the erase head.)
TypeSignalUsed for
3. Do not use a magnetized screwdriver for the adjustments.
WS-48B3 kHz, 0 dBTape Speed Adjustment
4. After the adjustments, apply suitable locking compound to the
parts adjusted.P-4-A10010 kHz, 10 dBHead Azimuth Adjustment
5. The adjustments should be performed with the rated power
Tape Speed Adjustment
supply voltage unless otherwise noted.
Setting:
Function: TAPE
Y Torque Measurement
ModeTorque MeterMeter Reading
test tape 2.95 6.86 mNm
WS-48B
FWDCQ-102C(30 70 gcm)frequency counter
(3 kHz, 0 dB)
(0.42 0.97 ozinch)
47 k&
0.15 5.39 mNm
FWD+
CQ-102C(1.5 5.5 gcm)set�
Back Tension
(0.021 0.076 ozinch)
more than 5.89 mNmMAIN board
SPEAKER terminal (CN17)
FFCQ-201B(more than 60 gcm)
(more than 0.83 ozinch)
more than 5.89 mNmProcedure:
REWCQ-201B(more than 60 gcm)
1. Playback WS-48B (tape center) in the FWD state.
(more than 0.83 ozinch)
2. Adjsut the volume in CAPSTAN/REEL motor so that the fre-
quency counter reading becomes 3,000 Hz.
Y Tape Tension Measurement
Specified Value: 2,970 to 3,030 Hz
ModeTension MeterMeter Reading
more than 100 g
FWDCQ-403A3. Confirm that the frequency at the beginning and that at the
(more than 3.53 oz)
end of tape winding are between 2,955 to 3,045 Hz.
Adjustment Location:
CAPSTAN/REEL
motor
Tape Speed
Adjustment
11 |