WSW17 (Function setting 2)
Selector
FunctionSetting and Specifications
No.
No. 1 2
0 0 :No alarm
1
0 1 :Always valid
Off-hook alarm
1 X :Valid except when
2
'call reservation'
is selected.
3Power failure report output0: ON1: OFF
Calendar clock/prompt alter-
40: NO1: YES
nate display
5Calendar clock type0: U.S.A. type 1: European type
6Error indication in activity report0: NO1: YES
7Non-ring reception0: OFF1: ON
8Not used.
lSelectors 1 and 2: Off-hook alarm
These selectors activate or deactivate the alarm function which sounds an alarm when the
communication is completed with the handset being off the hook.
lSelector 3: Power failure report output
This selector determines whether or not the equipment outputs a power failure report when
the power comes back on.
lSelector 4: Calendar clock/prompt alternate display
If this selector is set to "1," the calendar clock and the prompt "INSERT DOCUMENT" ap-
pear alternately on the LCD while the equipment is on standby; if it is set to "0," only the
calendar clock appears.
lSelector 5: Calendar clock type
If this selector is set to "0" (U.S.A.), the MM/DD/YY hh:mm format applies; if it is set to "1"
(Europe), the DD/MM/YY hh:mm format applies: DD is the day, MM is the month, YY is the
last two digits of the year, hh is the hour, and mm is the minute.
lSelector 6: Error indication in activity report
This selector determines whether or not a communications error code will be printed in the
activity report.
lSelector 7: Non-ring reception
Setting this selector to "1" makes the equipment receive calls without ringer sound if the ring
delay is set to 0.