WSW08 (Dial tone setting 2)
Selector
FunctionSetting and Specifications
No.
No. 1 2 3
0 0 0 :50 ms
10 0 1 :210 ms
0 1 0 :500 ms
|1st dial tone detection time0 1 1 :800 ms
length
1 0 0 :900 ms
3
1 0 1 :1.5 sec.
1 1 0 :2.0 sec.
1 1 1 :2.5 sec.
No. 4 5
0 0 : 10 sec.
4
Time-out length for 1st and 2nd0 1 : 20 sec.
dial tone detection1 0 :6 sec.(in the U.S.A versions)
5
15 sec.(in other versions)
1 1 : 30 sec.
No. 6 7 8
0 0 0 :-21 dBm
0 0 1 :-24 dBm
6
Detection level of 1st dial tone0 1 0 :-27 dBm
|and busy tone before dialing0 1 1 :-30 dBm
1 0 0 :-33 dBm
8
1 0 1 :-36 dBm
1 1 0 :-39 dBm
1 1 1 :-42 dBm
NOTE: The WSW08 is not applicable in those countries where no dial tone or line current de-
tection is supported, e.g., U.S.A.
lSelectors 1 through 3: 1st dial tone detection time length
Upon detection of the 1st dial tone for the time length set by these selectors, the equipment
starts dialing.
This setting is effective only when selectors 1 through 3 of WSW05 are set to "1, 1, 1."
lSelectors 4 and 5: Time-out length for 1st and 2nd dial tone detection
These selectors set the time-out length for the 1st and 2nd dial tone detection so that the
equipment waits dial tone input for the specified time length and disconnects itself from the
line when no dial tone is inputted.
V � 20 |