3. HALL AdjustmentProcessing after Completing Adjustments:
Order Page Address DataProcedure
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.169400Set the data.
269500Set the data.
SubjectNot required
Measurement PointDisplay data of page 1 (Note1)360100Set the data, and press PAUSE
button.
Measuring Instrument Adjustment remote commander460400Set the data.
Adjustment PageF
500100Set the data.
Adjustment Address17, 18, 19, 1A, 1B, 1C
Specified Value 115 to 19
Specified Value 285 to 89
Specified Value 385 to 89
Specified Value 415 to 19
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Switch setting:
POWER.................................................................. CAMERA
Adjusting method:
Order Page Address DataProcedure
100101Set the data.
269417Set the data.
369587Set the data.
46016D Set the data, and press PAUSE
button.
5602Check that the data changes to
O01�. (Note2)
660100Set the data, and press PAUSE
button.
Note2: The adjustment data will be automatically input to page: F, address:
17 to 1C.
Checking method:
Order Page Address DataProcedure
160403Set the data.
260101Set the data, and press PAUSE
button.
31Check that the IRIS display data
(Note1) satisfies the specified
value 1.
460103Set the data, and press PAUSE
button.
51Check that the IRIS display data
(Note1) satisfies the specified
value.2.
660169Set the data, and press PAUSE
button.
71Check that the ND display data
(Note1) satisfies the specified
value 3.
86016B Set the data, and press PAUSE
button.
91Check that the ND display data
(Note1) satisfies the specified
value 3.