2.12.1 MAGIC FOCUS Character Set-UpTABLE 1. - DCU PARAMETER
This instruction should be applied when a new DCU
ParameterNormalis being replaced.
Adjustment Preparation
ADJ. DISP77(1) Receive NTSC RF or video signal.
SEL. STAT00(2) With Power off, PRESS and HOLD the SERVICE
ONLY button on CONVER/FOCUS PWB, then pressDEMO WAIT2F
the Power On/Off, when picture appears releaseINT STEP 102
SERVICE ONLY switch. (Internal crosshatch isINT A DLY0A
displayed without conv. correction data.)INT C DLYFA
Adjustment ProcedureINT BAR1C
MGF STEP 1 00
(1) Press FREEZE key on R/C. (One additional line
MGF A DLY0A
MGF C DLYFAappears near the top and near the bottom.)
MGF BAR0E(2) Press PIPCH key, then ADJ. PARAMETER mode is
displayed as following.
SENSOR CK00
SENSOR 0FF
SENSOR 100
ADJ. PARAMETERSENSOR 2FF
ROM WRITE?SENSOR 301
ADJ. DISP. : 77SENSOR 4FF
SENSOR 506
SEL. STAT. : 00
SENSOR 6FFDEMO.WAIT : 2f
SENSOR 707
AD LEVEL03
E. DISPLAY00
(3) Press or key to change the ADJ. DISP. data.
ADJ. TIMS60(4) Press CURSOR to access DCU parameter.
AD LEVEL05Change the data as shown on Table 1, DCU
Parameter.AD NOISE80
PHASE MOT60
H. BLK-RV03
H. BLK-GV01
H. BLK-BV03
H. BLK-H00
PON DELAY0C
IR-CODE00
INITIAL 509E
MGF 5096
9 POINT 50FE
STAT 50FE
DYNA 509F
454545 |