Check that exposed parts are acceptably insulated from
the supply circuit before returning the repaired instrumentINSTRUMENT
to the customer.
? Checking methodChecking methodChecking methodChecking methodChecking method
Measure the resistance value between the both poles of(Exposed part)
attachment cup (Power supply plug) and the exposed
parts (Parts such as Knob, Cover, etc. where the cus-
tomer is easy to touch.) and check that the resistance
value is 500 kohms or more.
Insulation tester (DC 500V)
SAFETY PRECAUTIONSSAFETY PRECAUTIONSSAFETY PRECAUTIONSSAFETY PRECAUTIONSSAFETY PRECAUTIONS
The following precautions should be observed when servicing.
1. Since many parts in the unit have special safety-related characteristics, always use genuine Hitachi?s replacement
parts. Especially critical parts in the power circuit block should not be replaced with other makers. Critical parts
are marked with in the circuit diagram and printed wiring board.
2. Before returning a repaired unit to the customer, the service technician must thoroughly test the unit to ascertain
that it is completely safe to operate without danger of electrical shock.