PJ510 (C10S)PJ510 (C10S)
6-10 Related Messages
2PJ510 (C10S)T 23
message is displayed on the screen, please respond as described below.
MessageDescription
TO MAXIMIZE The unit does not display a warning message on the screen when the lamp expires or
PERFORMANCE,fails. When the lamp does not light, this indicates that the lamp is no longer functional
LAMP REPLACEMENTand should be replaced.
IS RECOMMENDED. Replace the lamp and do not forget to reset the timer.
NO INPUT IS DETECTEDThere is no input signal.
ON ***Check the signal input connection and the status of the signal source.
The horizontal or vertical frequencies of the inputted signal is outside of the operating
SYNC IS OUT OF RANGE
ON ***range limits of this unit. Please conżrm the specs for this unit or the signal source
specs.
The internal temperature is rising. Please turn the power OFF, then allow the unit to
imately 20 minutes. After having conżrmed the following items,
then please reset the power to ON.
CHECK THE AIR FLOW Is there blockage of the air lter?
Is the air lter dirty?
Does the ambient temperature exceeds 35C?
A note of precaution when cleaning the air lter.
CLEAN THE AIR FILTERPlease immediately turn the power off, and clean or change the air lter by referring to
POWER OFF FIRST,the Air Filter section of this manual. After you have cleaned or changed the air lter,
THEN CLEAN THE AIR FILTER.After cleaning the żlter, operate FILTER TIME of the OPTION Menu, then perform
AFTER CLEANING THE AIR reset of the lter timer.
FILTER, REST THE FILTER CLEAN THE AIR FILTER
TIMER.area of lter cover and the dust-detecting window, according to the following.
Note:
Although this message will be automatically disappeared after around 30 seconds, it will be reappeared
every time the power is turned ON.
2723 |