Message table
On-screen display
The following messages are displayed on the screen.
"CHANGE THE LAMP"
"AFTER REPLACING LAMP, RESETLamp has 1,700 hours on it and may need to be changed.
THE LAMP TIMER"
"CHANGE THE LAMP"
"AFTER REPLACING LAMP,
Lamp has 1,979 hours on it.
RESET THE LAMP TIMER"
See "Reset the lamp timer"
"THE POWER WILL TURN OFF
AFTER 20 Hr."
Blinking of "CHANGE THE LAMP"
"AFTER REPLACING LAMP,
When the lamp has 2,000 hours or more on it, the message will blink, and the
RESET THE LAMP TIMER"
power will turns off after 10 minutes.
"THE POWER WILL TURN OFF
AFTER 0 Hr."
"NO INPUT IS DETECTED" Signal is not in.
The horizontal or vertical frequency of the input signal exceeds the range of
"SYNC IS OUT OF RANGE"
the projector, it cannot be displayed.
"CHECK THE AIR FLOW"Please remove the obstruction before the suction port.
Indicator display
The ON indicator, LAMP indicator and TEMP indicator will light or blink in the following cases.
ON indicatorLAMP indicatorTEMP indicatorMeaningRemedy
Lights orangeGoes offGoes offStandby mode
Blinks greenGoes offGoes offDuring warming up
Lights greenGoes offGoes offDuring operation
Blinks orangeGoes offGoes offDuring cooling down
Cool projector by power off for
Lights redLights redGoes offLamp cannot light20 minutes.
If the indicator is still lit, lamp
may be defective. Replace.
Lamp is not inserted or Securely insert the lamp or
Lights redBlinks redGoes off
Lamp cover is openshut the lamp door.
Cooling fan accidented or PWBReplace fan, PWB ass'y SENSOR
Lights redGoes offBlinks red
ass'y SENSOR accidented.or connect CNTH.
Inside temperature becomes Please remove the obstruction
Lights redGoes offLights red
highbefore the suction port.
When inside temperature becomes high, to protect the projector, the lamp may be turned off and the lamp indicator
lights red, or the projector will be shut down and the all indicator display goes off.