CP-S335(C9SM)/CP-X340, PJ552 (C9X)/CP-X345, PJ562 (C9XM)
6-5 Air filter
WARNING
IBefore caring, make sure the power switch is off and the power cable is not plugged in, and then allow the
projector to cool suf ciently. The care in a high temperature state of the projector could cause a burn and/
or malfunction to the projector.
IUse only the air lter of the speci ed type. Do not use the projector with the air lter and lter cover
removed.
I Avoid wetting the projector or inserting liquids in the projector. It could result in a re, an electric shock,
and and/or malfunction to the projector.
CAUTION
IPlease replace the air lter when it is damaged or too soiled, and also when you replace the lamp.
When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible.
If the air filter becomes clogged by dust or the like, internal temperatures rise and the power may be auto-
matically turned off for malfunction prevention.
1. Turn the projector off, and unplug the power cord. Allow the projector to cool for at least 45 minutes. And
prepare a vacuum cleaner.
2. After making sure that the projector is cool adequately, slowly turn the pro-
Filter cover?s knob
jector so that the lens-side is facing up. Please be careful for a projector
not to fall. While the projector is placed lens-side up, hold the projector.
3. Putting a finger on the filter covers knob, slide the filter cover in the direc-
tion of the arrow to remove it.
Filter cover
4. Holding the air filters knob, pull the air filter off.
5. Apply a vacuum cleaner to the vent of the projector for the air filter. And
then slowly turn the projector bottom up.Air lter?s knob
6. Apply a vacuum cleaner to the air filter and filter cover.
Please replace the air filter when it is damaged or too soiled.
Use only the air filter of the specified type: NJ09702.
An air filter of specified type will come even with the replacement lamp for Air lter
this projector.
7. Position the cleaned air filter or a new air filter into place, and push the points of PUSH word with claws
to fix the air filter.
8. Replace the filter cover and snap it back into place.
9. Slowly turn the projector so that the top is facing up.
10. Turn the projector on, and reset the filter time.
(1) While projector running, press the MENU button of remote control or the [ ]/[ ]/[ ]/[ ] button of
keypad to open menu.
(2) Choose FILTER TIME in EASY menu or in OPTION of Advance menu.
(3) Press and hold RESET button of the remote control or [ ] button of the keypad for 3 seconds. FILTER
TIME reset window will appear.
(4) Choose RESET using [ ] button.
NOTE Incorrectly resetting of the lter timer (resetting without replacement, or neglect of resetting after
replacement) will result in incorrect message functions.