CP-S420WA(C7S2) / CP-X430WA(C7X2)CPX430W A(C7X2)
Replacing the Lamp
1. Switch the projector OFF, remove the power cord from the power outlet,
and wait at least 45 minutes for the unit to cool.
2. Prepare a new lamp.
20
down.
4. Loosen the two screws as shown in the diagram, and remove the lamp
cover.
5. Loosen the three screws, and gently remove the lamp while holding the
grips. Touching the inside of the lamp case may result in uneven coloring.
20
Also steadily push the opposite side of the screwed lamp into the unit.
20
8. Gently turn the projector right-side up.
CAUTION
20
tightened fully may result in injury or accidents.
Do not use the projector with the lamp cover removed.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp. When the lamp has been replaced after the LAMP indicator is red,
20
switching power ON. The power will be turned off automatically in over 10 minutes.
imately three seconds. The ?LAMP xxxx h? r
message will appear on the lamp timer on the bottom of the screen.
2. Press the MENU button on the remote control transmitter, or the RESET button on the control panel, while the
lamp timer is displayed. LAMPThe xxxx 0 CANCEL? message will then appear.
3. Press the and select 0, and wait until the timer display is cleared.
NOTE: Do not reset the lamp timer without replacing the lamp. Reset the lamp timer always when replacing the
2021 |