NOTE:Front cover
If the air filter is used when wet,suction is impaired
and the motor may be damaged.
*EXHAUST AIR FILTER(CV-80D, Fig.10,11)
HYGIENIC AIR FILTER(CV-80DC, Fig.10,11)
Your vacuum cleaner has a highly efficient Fig.10
electrostatic exhaust air filter(64)(65) to trap even the finest
dust particles in the exhaust air.
Once or twice a year,when the filter gets dirty,change
the filter as follows.Air filter
1. Open the front cover(62)(63).
2. Remove the old filter from the cleaner.
3. Fit a new filter in the cleaner.
*HEPA CLEAN FILTER(CV-80DP, Fig.12)
Your vacuum cleaner has a highly efficient electrostaticFig.11
exhaust air filter(64) to trap even the finest dust
particles in the exhaust air.HEPA clean filter
Once or twice a year,when the filter gets dirty,change the filter as
follows.
1. Open the front cover(62).
2. Remove the old filter from the cleaner .
3. Fit a new filter in the cleaner.
Fig.12
5. FINAL TEST
(1) After reassemblage,run the cleaner for at least 15 minutes and be certain that there in no abnormal vibration.
(2) Measure the insulation resistance between the power supply plug and the metal surface by 500V DC insulation
resistance tester and be certain that the insulation resistance is not less than 10M ohms. |