LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOW-
ING PAGES:
1. CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE FUSE.
2. CAUTION:
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, first check to see that all components in the power supply circuit are not
defective before you connect the AC plug to the AC power supply. Otherwise it may cause some compo-
nents in the power supply circuit to fail.
3. Note:
(1) Do not use the part number shown on the drawings for ordering. The correct part number is shown in the
parts list, and may be slightly different or amended since the drawings were prepared.
(2) To maintain original function and reliability of repaired units, use only original replacement parts which are
listed with their part numbers in the parts list section of the service manual.
4. Voltage indications for PLAY mode on the schematics are as shown below:
123
PLAY mode
(Unit: Volt)5.0 5.0
(2.5)STOP mode
The same voltage for Indicates that the voltage
both PLAY & STOP modesis not consistent here.
5. How to read converged lines
1-D3
31-B1
Distinction Area
AREA D3
Line Number
AREA B1
(1 to 3 digits)2
Examples:
1-D3
1. "1-D3" means that line number "1" goes to area "D3".1
2. "1-B1" means that line number "1" goes to area "B1".
ABCD
6. Test Point Information
: Indicates a test point with a jumper wire across a hole in the PCB.
: Used to indicate a test point with a component lead on foil side.
: Used to indicate a test point with no test pin.
: Used to indicate a test point with a test pin.