Adjustment > Adjustment Procedure
6-4 Adjustment Procedure
Start the adjustment program referring to ?6-2-6 Starting and Terminating Adjustment Program?.
For the subsequent operation, operate the PC mouse while watching the PC monitor screen.
Information:
1) Display ���� on subsequent PC screen shows the model name.
2) The numbers on PC screens show the operational procedure.
6-4-1 Data Initialize
Note:
Perform ?Data Initialize? only after replacing the MAN circuit board. Executing ?Data Initialize? will
initialize all adjustment data in EEPROM. After ?Data Initialize?, be sure to perform all adjustment
items.
ADJUST MENU screen
Procedure:MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
MODEL NAME: ����
1) Check DATA INITIALIZE on the ADJUST MENU
ADJUST MENU
screen.DATA INITIALIZE1
2) Click the EXECUTE button on ADJUST MENU screen,VIDEO LEVEL
BURST LEVEL
and then proceed with START TO SEND DATA? dialog.SAMPLING PULSE
AUTO FUCUS
3) Click the OK button in START TO SEND DATA? dialog:
AUTO IRIS CONTROL
After several seconds, ?Data Initialize? will finish andMATRIX
CHROMA GAIN
the ADJUST MENU screen will be restored. After that,STABILIZER
SPOT NOISE
be sure to perform all adjustment items.
LCD
EVF
2EXECUTERETURN
PLEASE SELECT ADJUST
START TO SEND DATA? dialog
DATA INITIALIZE
START TO SEND DATA?
OKCANCEL
3
6 - 21 |