ADFAdjustment
5.1.3.2 EEPROM Initialize and Sensor Adjustment5.1.3.3 Scan Stop Position Adjustment
This adjustment must be made after the control board unit is replaced.This adjustment must be made to adjust the scanning position after the
The EEPROM on the control board stores values for sensor sensitivity anddocument is transported into the ADF. It is performed by turning the rotary
scan stop position. Therefore, whenever you replace the control board,switch located under the switch cover at the top of the ADF.
you must perform EEPROM initialization, which is followed by the sensorThis adjustment, a user performable adjustment, must be separately
adjustment consecutively.made for the single feeding and reverse feeding. The table below shows
the rotary switch settings and corresponding amount shifted.
1. Set the ADF on the scanner.
Table 5-5. Switch Setting and Corresponding Shifting Length
2. Open the switch cover on the ADF and remove 1 screw securing the
rotary switch cover. Then remove the rotary switch cover.Rotary Switch Setting Amount shifted (mm)
3. Set the Dip-switches as shown below.00 (Reference position)
(+) value1mm / step
123 45(-) value1mm / step
ON
CHECK POINTAdjustment for the single and reverse feedings
üüüü
are made as follows:
[Single feeding] Made by controlling the rotational
OF Fnumber of the reverse motor after paper empty
condition is detected by the timing sensor.
[Reverse feeding] Made after paper empty
condition is detected by the reverse sensor
4. Open and then close either the paper eject cover or the paper feed
cover. (The EEPROM initialization and sensor adjustment mode is set
with this motion.)
5. Press the push button directly attached to the control board to run the
adjustment program, and EEPROM initialization and the sensor
adjustment for each sensor are carried out.
Rev. A5-9 |