AV14BJ8ENS / AV14BM8ENS
AV14BJ8EPS / AV14BM8EPS
AV14BJ8EES / AV14BM8EES
ADJUSTMENTS
    SCREEN ADJUSTMENT
Measuring
ItemTest point Adjustment part Description
instrument
SCREENRemoteSCREEN VR1. E nter SERVICE MENU.
adjustmentcontrol unit[On the FBT]2. Press YELLOW key to disable vertical scan.
3. Adjust SCREEN VR. on the FBT for a thin horizontal line like a
figure.
4. Press YE LLOW key again to enable vertical scan.
5. Press MENU key to leave service menu.
    ADJUSTMENT
Measuring
ItemTest point Adjustment part Description
instrument
IF adjustment RemoteIF 11. E nter SERVICE MENU.
control unit2. Select IF 1 with FUNCTION ( / ) key
IF 2
3. Press BLUE key during IF 1 is highlighted, IF 1 and IF 2 values
IF 3
are adjusted automatically by software.
IF 4
4. If the standard is L-prime, IF 3 and IF 4 values are adjustment
automatically when BLUE key is pressed during IF 1 is
highlighted.
    OSD HORIZONTAL POSITION ADJUSTMENT
Measuring
ItemTest point Adjustment part Description
instrument
HORIZONTALRemoteOSD1. Enter SERVICE MENU.
POSITION OFcontrol unit2. Select OSD with FUNCTION ( / ) key
OSD3. Adjust the OSD horizontal position with the FUNCTION ( / )
adjustmentSERVICE MENU SCREENkey, which shifts the reference bar on the bottom of the
SERVICE MENU horizontally, so that the OSD is positioned on
the screen center. (X=X?)
Reference bar
X X?
Screen size
16No. 51999 |