AV-14F3PX
Measuring
Item Test point Adjustment partDescription
instrument
Adjustment Remote2. BRIGHT1. Receive any broadcast.
ofcontrol unit2. Select the sub menu screen PICTURE from the SERVICE
SUBMENU.
BRIGHT3. Select 2. BRIGHT with the MENU 1/4 key, and confirm its
initial setting value.
4. If the brightness is not the best with the initial set value, make
fine adjustment until you get the best brightness, with the MENU
2/3 key.
Adjustment Remote1. PICTURE1. Receive any broadcast.
ofcontrol unit2. Select the sub menu screen PICTURE from the SERVICE
SUB CONT.MENU.
3. Select 1. PICTURE with the MENU 1/4 key, and confirm its
initial setting value.
4. If the contrast is not the best with the initial set value, make
fine adjustment until you get the best contrast, with the MENU
2/3 key.
Adjustment Remote[Method of adjustment without measuring instrument]
ofcontrol unit
SUB
COLOR -I3. COL. PALM(PAL-M COLOR)
1. Receive a PAL-M broadcast.
2. Select the sub menu screen PICTURE from the SERVICE
MENU.
3. Select 3. COL. PALM with the MENU 1/4 key, and confirm its
initial setting value.
4. If the color is not the best with the initial set value, make fine
adjustment until you get the best color, with the MENU 2/3
key.
4. COL. PALN(PAL-N COLOR)
1. Receive a PAL-N broadcast.
2. In the sub menu screen PICTURE , select 4. COL. PALN with
the MENU 1/4 key, and confirm its initial setting value.
3. If the color is not the best with the initial set value, make fine
adjustment until you get the best color, with the MENU 2/3
key.
5. COL. NTSC(NTSC COLOR)
1. Receive a NTSC broadcast.
2. In the sub menu screen PICTURE, select 5. COL. NTSC with
the MENU 1/4 key, and confirm its initial setting value.
3. If the color is not the best with the initial set value, make fine
adjustment until you get the best color, with the MENU 2/3
key.
No. 5608319 |