AV-21F8
Measuring
Item Test point Adjustment partDescription
instrument
Adjustment Remote [Method of adjustment without measuring instrument]
of BLACKcontrol unit
OFFSET-I
(SECAM)7.BLACK OFFSET 1. Receive a SECAM broadcast.
(R-Y)2. Select 2. V/C from the SERVICE MENU.
(B-Y)3. Select 7. BLACK OFFSET with the MENU a key.
4. Set the initial setting value for BLACK OFFSET (R-Y) and (B-
REMOTE CONTROL UNITY) with 4 and 7 or 6 and 9 keys on the remote control unit.
BLACK &5. If the picture is not the best with the initial setting value, make
WHITE OFF
123fine adjustment until you get the best picture.
BLACK &
WHITE ON6. Press the DISPLAY key twice to return to the normal screen.
456
R-Y ( )B-Y ( )
789
R-Y ( )B-Y ( )
Adjustment l Signal35 PIN (R-Y) [Method of adjustment using measuring instrument]
of BLACKgenerator36 PIN (B-Y)
OFFSET-IIIC 201 on
(SECAM)l Oscillo-MAIN PWB7BLACK OFFSET. 1. Receive a SECAM COLOUR bar signal (full field colour bar
scope (R-Y)75% white).
(B-Y)2. Select 2. V/C from the SERVICE MENU.
l Remote3. Select 7. BLACK OFFSET with the a key.
control4. Connect the oscilloscope between pin 35 of IC 201 and TP-E.
unit5. By using 4 and 7 keys on the remote control unit, adjust the
BLACK OFFSET (R-Y) so that the waveform changes from
(a) to (b) as shown in the figure.
[R-Y]6. Connect the oscilloscope between pin 36 of IC 201 and TP-E.
7. By using 6 and 9 keys on the remote control unit, adjust the
BLACK OFFSET (B-Y) so that the waveform changes fromFlatFlat
(c) to (d) as shown in the figure.
8. If the picture is not the best with the adjusted picture, make
fine adjustment until you get the best picture.
9. Press the DISPLAY key twice to return to the normal screen.
(a)(b)
[B-Y]
FlatFlat
(c)(d)
No. 5603520 |