4.3 MECHANISM COMPATIBILITY ADJUSTMENT4.4 ELECTRICAL ADJUSTMENT
4.3.1 Tape pattern adjustmentElectrical adjustment is performed by using a personal computer
NOTE:and software for SERVICE SUPPORT SYSTEM. Read
Prior to the adjustment, remove the cover (ADJUST).README.TXT file to use the software properly.
As for the connection of cables, see "4.2 JIG CONNECTOR
(1) Play back the compatibility adjustment tape.CABLE CONNECTION".
(2) While triggering the HID1, observe the waveform of
ENV_OUT.
(3) Set the manual tracking mode (ATF OFF).
(4) Confirm that the waveform is entirely parallel and straight,
and free from remarkable level-down, through the tracking
operation.
Make the confirmation as follows if necessary.
(5) If level-down is observed on the left hand side of the
waveform, straighten the level by turning the GUIDE
ROLLER (SUP).
If level-down is observed on the right hand side of the
waveform, straighten the
level by turning the GUIDE ROLLER (TU).
(6) After the adjustment, try the unloading motion once, and
confirm that the waveform is flat when the tape has been
played back again.
(7) Play back the self-recording.
(8) Confirm that the waveform is flat.
Flatten the waveform.
Misalignment of guide Misalignment of guide roller
roller height on the height on the take-up side
supply side
Fig.4-3-1
ENV_OUT
HID1
Fig.4-3-2
(No.86772)1-21 |