2.1.8 SYSTEM RESET
When the DIGITAL SIGNAL PWB is replaced or the DIGITAL
MAIN MENU SCREEN
INPUT is not normal, reset the SYSTEM SETTING using
the following procedure.SERVICE MENUSERVICE MENU
1.ADJUST 1.ADJUST
2.SELF_CHK 2.SELF_CHK
(1) Set to 0 minutes using the [SLEEP TIMER] key. 3.I2C STOP 3.I2C STOP
(2) Press the [VIDEO STATUS] key and [DISPLAY] key
simultaneously to enter the SERVICE MODE.
(3) When the Service Menu is displayed, press [2] key to
enter the self check mode.
(4) Turn off the power by pressing the [POWER] key on the
remote control unit.
SELF CHECK MODE SCREEN
LOB OK FAN OKLOB OK FAN OKSYNC M:OK S:OK HD:NGSYNC M:OK S:OK HD:NG
TIM OK TIM OK
When DIGITAL INPUT does not function normal using theMSM OK DIGI 0000MSM OK DIGI 0000
MEM OK AVSW OKMEM OK AVSW OK
method above mentioned, perform the following operation.YC OK AIO OKYC OK AIO OK
TUN OK GCR NG 1TUN OK GCR NG 1
IP OK RGB OK 8IP OK RGB OK 8
Remote control unit (with LC display) [LP20873-009] will DVI OK HDMI OKDVI OK HDMI OK
be required for this operation.
(1) Take out the batteries from the remote control unit.
(2) Insert the batteries while pressing and holding [4], [5] and
[6] keys simultaneously.
(3) While viewing the LC display of the remote control unit
(LP20873-009), set the value to [0] using the [START
DEBUT + ] / [START DEBUT - ] keys.
(4) In the same manner, set the value to [3] using the [STOP
FIN + ] / [STOP FIN - ] keys.
03-6C
(5) In the same manner, set the value to [6] using the [DATE + ]
/ [DATE - ] keys.
(6) In the same manner, set the value to [C] using the [PR + ]
/ [PR - ] keys.
(7) When completed with all of the above settings, press the
[Transmission] key.
123Transmitt
Button
456
798
0
++
STARTSTOP+DATE+PR
DUBITFIN--
--
1-10 (No.YA092B) |