DPX-5010
TEST MODE / ADJUSTMENT
How to enter the text mode Panel Mechanism Adjustment
While pressing on 1 and 3 keys, press the RESET kThe mechanism detects the open/close position of the paneley.
and writes it to the E2PROM.
Starting on the test mode
[ How to enter the test mode ]
Major initial positions
After entering the above-mentioned test mode, switch over
YWhen booted with everything off, the test mode starts up.
to the tuner mode. Then, press on the TI knob for some time
Y The valueof the volume is �40dB (indication is 15).
and the unit will go into panel mechanism test mode, which
Y FL lamps all light up.
is indicated by STAND-BY display.
Y The diversity is off.
Y Position: All.
Method:
Y EQ: Flat
Each time Open/Close key (*key) of the remote controller
Y COMPRESSOR: OFF
is pressed, full-open and full-close positions are registered.
Y SPE/ANA: PEAK HOLD
(There will be OPEN ENTRY/ CLOSE ENTRY display and
three beeps are sound.)
All display lamps lighting up
Since there are many segments on the display section,
Releasing:
bridging with other segments can be confirmed. By track up/
When TI key is pressed, the unit goes back to the previous
down keys, grids and segments can be lighted up individu-
test mode. Pressing the reset key will take the unit to the
ally.
initial condition.
Opening/Closing Time of the Panel Mechanism
DOLBY Adjustment
When each time the Angle/Retune button is pressed, time
Using the extension cord (W05-0755-00), separate the
is displayed after going into the tuner mode. From the maxi-
mechanism from the unit. Play the TCC-130 and adjust the
mum angle to return, it takes about 1.2S.
test round value to 300mV with the VR1, 2 on the X30 Board.
(Refer to the PC BOARD.) Balance with FWD and REV.
CD Mechanism Panel Disk Detection
Sensor behavior for detecting whether there is CD disk or
Releasing the Security Code
not can be checked. When the sensor is closed off after a
The unit will go into release mode when Preset 6 is pressed
disk is inserted, it beeps four times.
while Preset 1 is being pressed. The character OC� is dis-
played at the right end of the character display. At this point,
FM S-Meter Adjustment (Stop Adjustment and others)
input KCAR by using 1, 2, 3, and 4 key of the remote control-
Method:ler. Confirm with PLAY/PAUSE key and the security code will
SG Output: Set to 35dB? 98.1MHz. (with no modulation)be released.
During the above text mode, when Preset 1 and Preset 6.
are pressed at the same time, the adjustment begins. When Specifications for the Amplifier Control Terminal
adjustments is completed normally, OK is displayed and thereThe bass boost function of the amplifier can be remote
will be one beep of 2kHz. In this case the stop adjustment
control from the unit. This is a one-way communication, us-
values will be between 15~25dB?.
ing one control line. The control is made with pulse widths of
When the S-meter value is outside of the standard systemthe three kinds of communication data. Five cycle pulses are
control values, NG is displayed and the initial value of the
generated from the unit side and when there are three con-
system control is written in the E2PROM.
secutive successes, communication is established. The pulse
widths are as shown below and the cycle is 200ms.
AM Stop AdjustmentHI: 100ms
Method:LOW: 70ms
OFF: 40ms
SG Output: Set to 35dB? 999kHz. (with no modulation)
During the above text mode, when Preset 1 and Preset 6.
are pressed at the same time, the adjustment begins. When
adjustments is completed normally, OK is displayed and there
will be one beep of 2kHz. In this case the stop adjustment
values will be between 30~43dB? .
When the S-meter value is outside of the standard system
control values, NG is displayed and the initial value of the
system control is written in the E2PROM.
1111 |