PRECAUTION
WARNING FOR THE SAFETY-RELATED COMPONENT.WARNING
Y There are some special components used in LCDBE CAREFUL ELECTRIC SHOCK !
monitor that are important for safety. These parts are
marked on the schematic diagram and theY If you want to replace with the new backlight (CCFL) or
replacement parts list.It is essential that these criticalinverter circuit, must disconnect the AC adapter
parts should be replaced with the manufacturerOsbecause high voltage appears at inverter circuit about
650Vrms.
specified parts to prevent electric shock, fire or other
hazard.Y Handle with care wires or connectors of the inverter
Y Do not modify original design without obtaining writtencircuit. If the wires are pressed cause short and may
permission from manufacture or you will void theburn or take fire.
original parts and labor guarantee.
TAKE CARE DURING HANDLING THE LCD MODULE
WITH BACKLIGHT UNIT.
Y Must mount the module using mounting holes arranged
in four corners.
Y Do not press on the panel, edge of the frame strongly
or electric shock as this will result in damage to the
screen.
Y Do not scratch or press on the panel with any sharp
objects, such as pencil or pen as this may result in
damage to the panel.
Y Protect the module from the ESD as it may damage the
electronic circuit (C-MOS).
Y Make certain that treatment personOs body are
grounded through wrist band.
Y Do not leave the module in high temperature and in
areas of high humidity for a long time.
Y The module not be exposed to the direct sunlight.
Y Avoid contact with water as it may a short circuit within
the module.
Y If the surface of panel become dirty, please wipe it off
with a softmaterial. (Cleaning with a dirty or rough cloth
may damage the panel.)
CAUTION
Please use only a plastic screwdriver to protect yourself
from shock hazard during service operation.
- 3 - |