DMR-ES35VP / DMR-ES35VPC
ItemFL displayKey operation
Mode nameDescription(Remote controller key)
RAM Drive Last ErrorRAM Drive error code display.1. Error Number is displayed for 5Press [4] [2] in service mode.
*For details about the drive error code, referseconds.When?INFO******?isbeing
to the Service Manual for the specific RAMdisplayed, past 19 error histories
Drive.can be displayed by pressing [0] [1]
- [1] [9]
2. Time when the error has occurred
is displayed for 5 seconds.
DD: Day
hh: Hour
mm: Minute
3. Last Drive Error (1/2) is displayed
for 5 seconds.
4. Last Drive Error (2/2) is displayed
for 5 seconds.
5. Error occurring Disc type is
displayed for 5 seconds.
6. Disc Maker ID is displayed for 5
seconds.
In case that the maker cannot be
identified, display is black out.
7. Factor of Drive Error occurring is
left displayed
Delete the Last DriveDelete the Last Drive Error information storedPress [9] [6] in service mode.
Erroron the DVD RAM-Drive.
Laser power confirmation Drive state is judged based on difference 1. into RAM
between laser power value at shipping andDrive in service mode. (Other
present laser power value.media are assumed to be non-
correspondence.)
2. Press [4] [4].
If DVD-RAM disc in not inserted,
[NO DISC] is displayed.
If power value study was filed,
[ERROR] is displayed.
Turn on all FL/LEDsAll segments of FL and all LEDs are turnedAll segments are turned on.Press [5] [1] in service mode.
on.
S1 signal outputForcibly superimpose the S1 signal (approx.Press [5] [2] in service mode.
4.5V DC) on the EE chroma signal, and check
the output on the S terminal.
S2 signal outputForcibly superimpose the S2 signal (approx.Press [5] [3] in service mode.
2V DC) on the EE chroma signal, and check
the output on the S terminal.