AVX-P7000CD
- Discharging operations
1. When the OPEN key or the ACC is turned OON�(or
detach grille installing ), (2 sec. after) the position
motor will be activated under the high speed mode.
2. When the longitudinal position sensing switch (PUSH
SW)/(LIFT SW) turns H - L, the position motor will be
stopped and, at the same time, the angle motor will
be activated at high speed.
3. When the electric potential of the angle encoder
reaches 90! (Reference 0! potential + 3.047V), the
90! potential or
angle motor will be stopped. (Braking mode) the memorized
However, if the preceding angle is being memorized,position
the angle motor will keep running until the
memorized angle can be obtained.
- Storage operation
1. When the CLOSE key is operated (or 6 sec. after
turning OOFF� the ACC while the automatic open-
close setting is being turned OON�), the angle motor
will be activated at low speed.
2. At 750ms after the angle 0! potential has been
reached, the angle motor will be stopped and the
position motor will be activated at high speed. The
system will go into stopping movement at the point
where the PULL SW is turned OON� by detection or
when the error time is over.
67 |