CDX-P650
- CD Player Service Precautions
1. For pickup unit(CXX1285) handling, please refer3. Please checking the grating after changing the pickup
to"Disassembly"(See page 40). During replacement,unit(see page 29) since these screws protects the
handling precautions shall be taken to prevent anmechanism during transport, be sure to affix it when
electrostatic discharge(protection by a short pin).it is transported for repair, etc.
2. During disassembly, be sure to turn the power off
since an internal IC might be destroyed when a con-
nector is plugged or unplugged.
Transportation of multi-CD Player
Seal
After removing the transport screw, cover the hole
with the supplied seal.
Transport screw
Attach to the original position before transporting the set.
A transport screw has been attached to the set in order to protect
it during transportation. After removing the transport screw,
cover the hole with the supplied seal. Be sure to remove the
transport screw before mounting the set. The removed transport
screw should be retained in the accessory bag for use the next
time the set is transported.
2 |