CDX-P656,P25
KeyMechanism Test Mode
(Example)
BANDBack to the test mode
UPPlaying the mechanism
DOWNPlaying the mechanism
7Mechanism test mode in
8�
9TRAY/ELV select
10�
11�
12Operation step select
Note: Eject and CD on/off is performed in the same procedure as that for the normal mode.
(3) Cause of Error and Error Code
Code ClassContentsDescription and cause
40Electricity Off focus detected.FOK goes low.
? Damages/stains on disc, vibrations or failure on servo.
41Electricity Spindle unlocked.FOK = Low continued for 50 msec.
? Damages/stains on disc, vibrations or failure on servo.
42Electricity Sub-code unreadable.Sub-code was unreadable for 50 msec.
? Damages/stains on disc, vibrations or failure on servo.
43Electricity Sound skipping detected.Last address memory function was activated.
? Damages/stains on disc, vibrations or failure on servo.
Note: Mechanical errors during aging are not displayed.
The error codes should be indicated in the same way as in the normal mode.
(4) Display of Operational Status (CPOINT) during Setup
Status No. ContentsProtective action
00CD+5V ON process in progress.None
01Servo LSI initialization (1/3) in progress.None
02Servo LSI CRAM initialization in progress.None
03Servo LSI initialization (2/3) in progress.None
04Offset adjustment (1/3) in progress.None
05Offset adjustment (2/3) in progress.None
06Offset adjustment (3/3) in progress.None
07FZD adjustment in progress.None
08Servo LSI initialization (3/3) in progress.None
10Carriage move to home position started.None
11Carriage move to home position started.None
12Carriage is moving toward inner diameter.Specified 10 seconds has been passed or failure
on home switch.
13Carriage is moving toward outer diameter.Specified 10 seconds has been passed or failure
on home switch.
14Carriage outer kick in progress.None
15Carriage outer diameter feed (1 second) in progress. None
20Servo close started.None
21Pre-processing for focus search started.None
22Spindle rotation and focus search started.None
23Waiting for focus close (XSI=Low).Specified focus search time has been passed.
24Standing by after focus close is over.Specified focus search time has been passed.
25Focus search preprocessing is in None
progress while setup protection is turned on.
46 |