4. How to Start-up the Test Mode
Specifications for Operation
A
Operation Method
RESET start while pressing TA (CLOCK) + LIST.
?
DEH device name is displayed.
*In case the test is conducted
as destined for ES, TA CLOCK will be displa?yed.
?Phone + BAND key
Standby for connection from the device (mobile phone, etc.)
B
Connection from DEH to the device cannot be made.
?Device connection completed
Device name is displayed.
When the connection is completed, the name of the connected
device will be displayed. (MAX 12 one-byte characters)
ANTENNA is checked automatically.
?ANTENNA check complete (automatic)
The result of ANTENNA check is displayed. The value is only a
guideline. The ANTENNA level displayed is -80 to -18.
C
If an ANTENNA value outside of the range is displayed after con-
nection,check the condition of the unit and try from the beginning
again.
?Center key
SKIP the following two items by pressing the Center key as they
are the ones checked at the time of manufacturing.
?Center key
D
Center key
?
Start FLASH check.
E
?FLASH check complete
FLASH check is conducted automatically according to the followi-
ng steps.
Delete ? Write Read ?T? otally delete Read?
Read out the written data, and verify that both of them match.
Read out after total delete, and verify that the deletion has been
accomplished. Verification is OK if OK is displayed.
Test is complete if everything progressed normally up to this point.
F
DEH-P75BT/XN/EW5
74