DV-535
Description
FLCauses if with a DVDCauses if with a CDOperation of the
of Error
SGC converge
39SGC could not converge during detects the peakOpen
timeout
41 Spindle timeoutThe unit did not enter Stop mode within 10 seconds of issuance of a Stop command.Stop
The spindle could not converge into within ? 12% of
the target FG rotation speed within 10 seconds after
spindle kick. The first time after startup (the first time
Spindle FG after disc distinction), it doesn't become the number of
48Stops. (FG timeout)
transition timeoutthe target rotation within five seconds. The first time
after startup, detects the abnormal rotation number of
high-speed continuously 3 loops. DVD: 5 to 9 mS ,
CD: 40 to 60 mS
After the second times after startup, it doesn't become the number of the target rotation Stops.
Spindle PLL
49within five seconds. Detects the abnormal high-speed or low-speed rotations.("73" is displayed during DVD: 5 to
transition timeout
9 mS , CD: 40 to 60 mSstarting process.)
Stops.
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB.("73" is displayed during
starting process.)
Auto sequence ABUSY did not return within 1 second after the
51Stop
timeout of peak DDTCT (peak detection) command was sent.
Auto sequence
ABUSY did not return within 30 mS after the FJMPD
52timeout of focus Stop
(Focus jump 1 to 0) command was sent.
jump down
Auto sequence ABUSY did not return within 30 mS after the FJMPU
53Stop
timeout of focus (Focus jump 0 to 1) command was sent.
Auto sequence ABUSY did not return within 50 mS after the GSUMON
54Stop
timeout of play AGC(play-AGC-measuring) command was sent.
Auto sequence
ABUSY did not return within 2 seconds after the
55timeout of disc-type-Stop
DJSRT (disc-sensing) command was sent.
sensing
Auto sequence ABUSY did not return within 1 second after the
56TBLOFS (Internal ATB after the completion of external Stop
timeout of ATB2
ATB) command was sent.
Auto sequence
ABUSY did not return within 500 mS after the TSON
57timeout of tracking Stop
(tracking servo ON) command was sent.
servo ON
Auto sequence ABUSY did not return within 200 mS after the TBL
58Stop
timeout of ATB1(external ATB) command was sent.
Auto sequence
ABUSY did not return within 2 seconds after the FGN
59timeout of focus gain Stop
(focus gain adjustment) command was sent.
adjustment
Auto sequence ABUSY did not return within 2 seconds after TGN
5Atimeout of tracking Stop
(tracking gain adjustment) command was sent.
gain adjustment
Auto sequence
ABUSY did not return within 1 second after the
5Btimeout of offset Stop
CMDAVE (offset adjustment) command was sent.
adjustment
Auto sequence
ABUSY did not return within 200 mS after the ADJMIR
5Ctimeout of Stop
(modulation factor measurement) command was sent.
modulation factor
measurement
Auto sequence
ABUSY did not return within 2 seconds after the AFB
5Dtimeout of auto focus Stop
(auto focus bias) command was sent.
bias
A command could not be sent because ABUSY was
Auto sequence
5Flow. ABUSY did not return within 200 mS after TLV Stop
already busy
command was sent.
Pause mode could not be restored within three retries
62 Pause retry errorContinues operation
after it had been released.
55 |