F. ADJUSTMENT PROCEDURE
ITEM ýTest Meter
Adjusting
yTest Point Operation
Program Menu. Value
>Pattern
B+ ýDigital Voltmeter 1. Make the adjustment to the value shown at right 15.5V
Adjust yD510 Negative by turning the VR501 on the main PCB. 20.2V
A
>Crosshatch Pattern
(31.5KHz,640x480)
High Voltage ýDigital Voltmeter 1. Turn the power switch of the monitor OFF. 26.0KV
Adjust ýHigh Voltage 2. Connect high voltage probe to Anode Cap and (17?,19?)
GND. 25.0KV
Probe
3. Turn the power switch of the monitor ON. 20.1KV
B yAnode Cap-GND
(15 minutes) (15?)
>Crosshatch Pattern
4. Make the adjustment to the value shown at right
(31.5KHz,640x480)
by turning the VR601 on the main PCB.
Preset >Crosshatch 1. Turn the power switch of the monitor OFF. Contrast :
Adjust (31.5KHz,640x480) 2. Hold encorder key,then turn the power switch of MAX.
the monitor ON.(one key type) Brightness
Hold MENU key,then turn the power switch of MAX.
the monitor ON.(four key type) H-Size :
3. Turn encorder/MENU key,make sure into preset 260mm(15?)
picture,if not ,please return 1-2. 310mm(17?)
4. Please following the procedure of selection and 360mm(19?)
adjusting an item using the OSD system as below V-Size :
steps for main function adjusent. 190mm(15?)
One key model : 230mm(17?)
Step 1 : Press and relese the OSD control knob to 270mm(19?)
activate the OSD menu. H-Posi. :
Step 2 : Turn the knob to highlight the desired option Center
C
of OSD icon. V-Posi :
Step 3 : Press and release the knob again to access Center
the option. The color of the inner area of the
OSD will changed from blue to green.
Step 4 : To make your adjustment,turn the knob
clockwise to increase or countclockwise
to decrease the setting.
Step 5 : Press and release the knob again to store
the change.the color of the inner area will
go back to blue.You can select EXIT icon
and press the knob the exit the OSD menu.
11 |