CORNER ADJUSTMENTVERTICAL HEIGHT ADJUSTMENT
1. Receive cross hatch pattern and set screen mode to1. Receive circular pattern and set screen mode to
OFULL�.OFULL�.
2. Enter to the service mode and select mode OWIDE�,2. Enter to the service mode and select mode OWIDE�,
and select item no. 10 OWIDE 10.P CNR�.and select item no. 5 OWIDE 5.P V-S.
3. Press the LEVEL+ or LEVEL - button to correct the3. Press the LEVEL+ or LEVEL - button to adjust the
distortion of the vertical line around the corners.vertical height.
HORIZONTAL ADJUSTMENT
HORIZONT AL CENTRING ADJUSTMENT
1. Receive circular pattern and set screen mode to
OFULL�.
2. Enter to the service mode and select mode OWIDE�,
and select item no. 2 OWIDE 2.P H-P�.
3. Press the LEVEL+ or LEVEL - button to adjust the
horizontal centre.
OSD POSITIONING ADJUSTMENT
HORIZONT AL WIDTH ADJUSTMENT1. Receive circular pattern and set screen mode to
1. Receive circular pattern and set screen mode toOFULL�.
OFULL�.2. Enter to the service mode and select mode OREGU-
2. Enter to the service mode and select mode OWIDE�,LAR�, and select item no. 8 OREGULAR 8 OSD�. The
and select item 6 OWIDE 6.P H-W�.OSD test bar will appear on the top of screen.
3. Press the LEVEL+ or LEVEL - button to adjust the3. Press the LEVEL+ or LEVEL - button to adjust prop-
horizontal width.er OSD positioning.
zzzzzzzzzzzzzzzzzzzz
HIGH-VOLTAGE CONFIRMATION
1. Receive circular pattern and set screen mode to
OFULL�.
2. Set controls to normal.
3. Connect high-voltage meter to the anode of CRT and
GND.
4. Confirm that voltage is 26.0?1.0kV at 1.4mA for 28�
model.
VERTICAL ADJUSTMENT
VERTICAL CENTRING ADJUSTMENT
1. Receive circular pattern and set screen mode to
OFULL�.
2. Enter to the service mode and select mode OWIDE�,
and select item no. 1 OWIDE 1.P V-P�.
.3 Press the LEVEL+ or LEVEL - button to adjust the
vertical centre.
-11-
C2WYV |