Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP 14SL30 Repair Manual

$7.99

SHARP 14SL30 - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Charles Dussier - 12/05/2006 5 of 5 Stars!
Super vraiment excellent! la qualit� d'image est vraiment au rendez vous. fichier recuperrable dans la journ�e c'est impeccable! Fichier qui etait introuvable, je l'ai enfin ! merci !!:)
Steve Fink - 07/24/2006 5 of 5 Stars!
Nice, really nice. I was happy to receive manual in true electronic form, instead of scanned original. This manual includes: Wiring diagram, circuit diagram, block diagram, PC board, adjustment, exploded view, PARTS CATALOG and more.. It's full color manual, not B&W or grayscale :)
ivan radic - 02/03/2007 5 of 5 Stars!
Super fast!Excellent quality and solid transaction!I will return.Thanks
oleg volkozub - 09/25/2008 5 of 5 Stars!
Very nice clear manual with specifications, thanks!
Patrick Guice - 04/23/2008 5 of 5 Stars!
Phenomal manual great resoulution and very legible. Will become very helpfull in future for parts and service.

Customers who bought this product also purchased
SHARP 10P35G Service Manual
SHARP 10P35G Service Manual
SHARP 14BN14 Service Manual
SHARP 14BN14 Service Manual
SHARP 14BM CHASSIS Service Manual
SHARP 14BM CHASSIS Service Manual
SHARP 10P16S Service Manual
SHARP 10P16S Service Manual
SHARP 14BN1 Service Manual
SHARP 14BN1 Service Manual
SHARP 29AS41 Service Manual
SHARP 29AS41 Service Manual

Click to see text excerpt from the manual
14SL30
21SL40, 21SL70
e SERVICE ADJUSTMENT
VCO AdjustmentWhite Balance Adjustment
1. Connect a digital voltmeter between pin (44) of IC2011. Receive a good local channel.
and ground.2. Enter the service mode and select the service
2. Receive a good local channel.adjustment "S03" and set to "00" (minimum
3. Enter the service mode and select the servicecolor)(Record original data code under adjustment
adjustment "S10"."S03" before changing). "S03" does not have to be
4. Adjust the data so that digital voltmeter reads 2.2Vadjusted, if you selected a B/W picture or monoscope.
5. Adjustment is completed, remove the voltmeterpattern.,
return to "normal" mode.3. Alternately adjust the service adjustment data of "S14"
and "S15" until a good grey scale with normal whites
RF AGC Adjustmentis obtained.
1. Receive a good local channel.4. Select the service adjustment "S03" and adjust data
to obtain normal color level.
2. Enter the service mode and select the service
adjustment "S08".Sub-Picture Adjustment
3. Set the data value to point where no noise or beat
appears.1. Receive a good local channel.
4. Select another channel to confirm that no noise or2. Make sure the customer picture control is set to
beat appears.maximum.
Note 1 :You will have to come out of the service3. Enter the service mode and select the service
mode to select another channel.adjustment "S01".
Note 2 :Setting the data to "00" will produce a black4. Adjust the data value to achieve normal contrast
raster.range.
Screen AdjustmentSub-Tint Adjustment
1. Connect a digital voltmeter between TP852 and1. Receive a good local channel.
TP853 on the CRT Unit.2. Set customer tint control to center of it's range.
Note:These test points may not be provided.3. Enter the service mode and select the service
Then connect the voltmeter to both ends ofadjustment "S02".
R852 located near Q852 on the foil side.4. Adjust "S02" data value to obtain normal flesh tones.
2. Receive a good local channel.
3. Enter the service mode and select the serviceSub-Color Adjustment
adjustment "S03" and set the data value to "00" to
set the color level to minimum. (Record original data1. Receive a good local channel.
code under adjustment "S03" before changing) You2. Make sure the customer color control is set to center
position .
may skip this step, if you selected a B/W picture or3. Enter the service mode and select the service
monoscope pattern.
4. Select the service adjustment "S19" and adjust theadjustment "S03".
data value to "01", this turn off the luminance signal4. Adjust "S03" data value to obtain normal color level.
(Y-mute).
5. Select the service adjustment "S04" and adjust data
value to obtain 0.17 volts on the digital voltmeter.
6. Adjust the master screen control until the raster
darkens to the point where raster is barely seen.
7. Adjust the service adjustments "S11" red, "S12" green
and "S13" blue to obtain a good grey scale with
normal whites at low brightness level.
8. Select the service adjustment "S19" and reset data
to "00". Select the service adjustment "S03" and reset
data to obtain normal color level.
9. Remove digital voltmeter, and reset the master screen
control to obtain normal brightness range.
8
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-85DTSB
RD-85DTSB
Quick Start

$4.99
Current Parse Time: 0.392 s with 42 queries. Queries took 0.040631