21B-FX1
?? ????? ? ?? ? ??
SUB ADJ.ADJ.ADJ.SUB ADJ.
MODEMODEMODEMODE
Y-DELAYOFFSET
FORWARD : CH DOWN KEY REVERSE : CH UP KEY * ( ) means OSD display.
Max Volume (SUB-VOL) Sub Contrast (SUB-CON) Sub Colour (SUB-COL) Sub Brightness (SUB-BRI) Sub Tint (SUB-TINT)Sub Sharpness (SUB-SHP) Max Hotel Volume (HTL-VOL) Hotel Program number (HTL-PRG) Blue Back Contorast (BB-CON) OSD RGB Reference (RGB) Black Level off-set R (CUT-R) Black Level off-set G (CUT-G) Cathode Drive Level (CDL)
3-2
IC? ? ? ? ? ? ? ? ?
ADJ.ADJ.
MODEMODEMODEOPTION
WHITE POINTWHITE POINT
White point Red Standard white temp.(DRI-RS) White point Green Standard white temp. (DRI-GS) White point Blue Standard white temp (DRI-BS) White point Red Cold white temp. (DRI-RC) White point Green Cold white temp. (DRI-GC) White point Blue Cold white temp. (DRI-BC) White point Red Warm white temp. (DRI-RW) White point Green Warm white temp. (DRI-GW) White point Blue Warm white temp. (DRI-BW)
?? ? ? ? ? ? ? ? ? ? ? ?
AGC &MODEMISC.MODEAGC &MODE
OPTION
GEOMETRICGEOMETRIC
SERVICE MODE
AGC Take Over Point (AGC) Vertical Slope (V-LIN) Vertical Amplitude(V-AMP) Vertical Shift (V-CENT) Horizontal shift (H-CENT) East-West width (H-SIZE) Horizontal Parallelogram (EW//) East-west Parabola/Width (PARA) East-west Upper Corner Parabola (COR(U)) East-west Lower Corner Parabola (COR(L)) East-west Trapezium (TRAPE) Horizontal Bow (HB) S-Correction (S-COR)
(1) In the Service Mode, Key is used to select the mode in the following order.FORWARD : CH DOWN KEY REVERSE : CH UP KEY * ( ) means OSD display.
C bus control and in the conventional
2
2IC1003EEP ROM3IC801TVPROCESSOR4IC401AV SWITCH5IC305SOUND PROCESSOR6IC2300IGR(/NICAM) DECODER8TU201TUNER3-1
2C bus control include preset-only items and variable data.
ADJUSTMENT PRECAUTIONS
LED (RED) flashing:Flashing timePart's Ref.No.Remarks
mode. (Adjustment through the I2C bus control). (Use JWS Key to set as well).is in out of the service mode.Initial values are automatically preset, only when a new EEPROM is used (Judge with the first 4 bytes).
. Short TP1001 & TP1002 to switch to the service mode position, and the microprocessor is in input. Press the CH DOWN / UP key on the remote controller to get ready to select the mode one by one.. Press the CH DOWN / UP key on the remote controller to select the modes reversibly one by one.. Using the VOLUME UP/ DOWN key on the remote controller, the data can be modified.. Disconnect TP1001 & TP1002 to switch to the normal mode (OFF) position, and the microprocessor. Short TP1001 & TP1002 to switch to the service mode position and turn on the main power switch.. The initial data are preset as listed in page 4, 5, & 6.. Make sure the data need modify or not (Initial data).
12345123make sure to short TP1001 & TP1002 to switch to the service mode position first and then turn on the main power switch (See 2-(1) above).Precaution: If havenOt done this initiation, it may possibly generate excessive Beam current.If the set is interrupted by IIC bus line error, the following indicators work to identify a spot in trouble.
(UAF Series type RH-IX3416CE, RH-IX3414CE Attachment)
This modelOs setting are adjusted in two different ways: through the Ianalog manner. The adjustments via the I1. Setting the service mode by the microprocessor.2.Factory Presetting.Note:Once the chassis has been assembly together and ready to be POWER ON for the FIRST TIME,3.For reference please check with memory map4.Trouble indications
3 |