32L-S500,32L-X2000
CL32S50,36L-X2000
SERVICE ADJUSTMENT
Screen AdjustmentSub-Tint Adjustment
1. Receive a good local channel.1. Receive a good local channel.
2. Enter the service mode and select the service No.2. Set customer tint control to center of it's range.
"S11" and set the data value to "00" to set the color3. Enter the service mode and select the service No.
level to minimum. (Record original data code under"S10".
No. "S11" before changing) You may skip this step, if4. Adjust "S10" data value to obtain normal flesh tones.
you selected a B/W picture or monoscope pattern.
3. Select the service No. "S21" and adjust the data valueSub-Color Adjustment
to "01", this turn off the luminance signal (Y-mute).
4. Select the service No. "S12" and adjust data value to1. Receive a good local channel.
2. Make sure the customer color control is set to center
"58".
5. Adjust the master screen control until the rasterposition .
3. Enter the service mode and select the service No.
darkens to the point where raster is barely seen.
6. Adjust the service numbers "S16" red, "S17" green"S11".
and "S18" blue to obtain a good grey scale with normal4. Adjust "S11" data value to obtain normal color level.
whites at low brightness level.
7. Select the service No. "S21" and reset data to "00".Sub-Brightness Adjustment
Select the service No. "S11" and reset data to obtain1. Receive a good local channel.
normal color level.2. Make sure the customer brightness control is set to
8. Reset the master screen control to obtain normal
center position.
brightness range.3. Enter the service mode and select the service No.
"S12".
White Balance Adjustment4. Adjust "S12" data value to obtain normal brightness
level.
1. Receive a good local channel.
2. Enter the service mode and select the service No.
"S11" and set to "00" (minimum color)(Record originalVertical Linearity Adjustment
data code under adjustment "S11" before changing).1. Receive a good CATV channel.
"S11" does not have to be adjusted, if you selected a
2. Set to standard setting mode.
B/W picture or monoscope pattern.3. Enter the service mode and select the service No.
3. Alternately adjust the service numbers "S19" and
"S02".
"S20" until a good grey scale with normal whites is4. While observing the top and bottom of the screen,
obtained.adjust "S02" data value to proper vertical linearity.
4. Select the service No. "S11" and adjust data to obtain
normal color level.Vertical Phase Adjustment
Sub-Picture Adjustment1. Enter the service mode and select the service No.
"S14".
1. Receive a good local channel.2. Adjust data value to "00".
2. Make sure the customer picture control is set to
Note:This must be set "00" when changed data
maximum.retrace line will appear.
3. Enter the service mode and select the service No.
"S09".
Vertical-Size Adjustment
4. Adjust the data value to achieve normal contrast
range.1. Receive a good local channel.
2. Enter the service mode and select the service No.
"S01".
3. While observing the top and bottom of the screen,
adjust "S01" data value to proper vertical size.
11 |