Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP AE-X099E Repair Manual

$7.99

SHARP AE-X099E - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Jim Carrier - 08/02/2006 5 of 5 Stars!
Outstanding and fast service! I received service manual in a moment after order. Thanks to this manual I can use my printer again!
Patrick Guice - 04/23/2008 5 of 5 Stars!
Phenomal manual great resoulution and very legible. Will become very helpfull in future for parts and service.
Krzysztof Mazurek - 11/27/2007 5 of 5 Stars!
Super ! Szukałem wszędzie i tutaj po 10 minutach miałem schemat w swoim PC.
Roger Mason - 07/28/2006 5 of 5 Stars!
Man, I was looking for this manual for a while! Where do You get them?;) Of course, quality is goooood:) Anyway, I can only say: A+A+A+!
Henry Seiden - 02/26/2009 5 of 5 Stars!
I downloaded this product and looked through it quickly with Adobe Reader v9. It is clean and a good copy. Some scanned pages are not perfectly square, but that is a minor complaint. The document schematics and board diagrams are easy to read, of good contrast. The whole file downloaded quickly. This is a good service! Sony charges about $100 for the printed version of the same manual. It is still available through their print-on-demand pro parts system, but why would you do that?

Customers who bought this product also purchased
SHARP 115U_OM.pdf Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 14BN1 Service Manual
SHARP 14BN1 Service Manual
SHARP 10P35G Service Manual
SHARP 10P35G Service Manual
SHARP 14BN14 Service Manual
SHARP 14BN14 Service Manual
SHARP 20PL83 Service Manual
SHARP 20PL83 Service Manual
SHARP 10P16S Service Manual
SHARP 10P16S Service Manual

Click to see text excerpt from the manual
AH-X079E/X099E
AY-X079E/X099E
2-2 Frequency control
(1) AC current peak control
Set value (Normal)
Model
During coolingDuring heating
AU-X079E5.8A
AU-X099E6.0A
AE-X079E5.8A6.3A
AE-X099E6.0A6.5A
(2) Control for prevention of indoor heat exchanger overheating
If the temperature of the indoor heat exchanger exceeds the overheating prevention line 1 or 2 during heating, the
operating frequency is lowered by approximately 5 to 10 Hz.
After that, the frequency is lowered by approximately 5Hz once every 60 seconds or 10 Hz once every 120 seconds.
When the temperature of the indoor heat exchanger goes below the overheating prevention line 1, the frequency is
raised by approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the frequency is lowered to 15 Hz without the temperature of the outdoor heat exchanger decreasing and this
condition lasts for 1 minute, the compressor will be stopped.
Overheating prevention line 1 (Lower 5Hz)
Operating FrequencyAbove
92 to
88 to
83 to
75 to
50 to
43 to
Below

92Hz88Hz83Hz75Hz50Hz43Hz37Hz37Hz
During Normal Operation 51uC52uC53uC54uC53uC52uC50uC46uC
During Full Power Operation54uC56uC57uC58uC56uC55uC52uC49uC
Overheating prevention line 2 (Lower 10Hz)
Operating FrequencyAbove
92 to
88 to
83 to
75 to
50 to
43 to
Below

92Hz88Hz83Hz75Hz50Hz43Hz37Hz37Hz
During Normal Operation 53uC54uC55uC56uC55uC54uC52uC48uC
During Full Power Operation56uC57uC58uC60uC58uC57uC54uC51uC
(3) Control for prevention of outdoor heat exchanger overheating
If the temperature of the outdoor heat exchanger exceeds the overheating prevention lone 1 or 2 during cooling, the
operating frequency is lowered by approximately 5 to 15 Hz.
After that, the frequency is lowered by approximately 5 once every 60 seconds or approximately 15Hz once every
120 seconds.
When the temperature of the outdoor heat exchanger goes below the overheating prevention clear line, the
frequency is raised by approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the frequency is lowered to 15 Hz without the temperature of the outdoor heat exchanger decreasing and this
condition lasts for 1 minute, the compressor will be stopped.
Overheating prevention line 156uCLower 5Hz once every 60 seconds
Overheating prevention line 158uCLower 15Hz once every 120 seconds
Overheating prevention line 155uC
(4) Control for prevention of discharge overheating
If the discharge temperature exceeds approximately 105°C during compressor operation, the operating frequency
is lowered by approximately 5 Hz.
After that, the frequency is lowered by approximately 5 Hz once every 60 seconds. When the discharge temperature
goes below approximately 104uC, the frequency is raised by approximately 5 Hz once every 60 seconds, and
normal operation is restored.
If the frequency is lowered to 15 Hz without the discharge temperature decreasing and this condition lasts for 1
minute, the compressor will be stopped.
(5) Control for prevention of indoor heat exchanger freezing
If the temperature of the indoor heat exchanger goes below approximately 5°C during cooling, the operating
frequency is lowered by approximately 5 Hz.
After that, the frequency is lowered by approximately 5 Hz once every 60 seconds.
When the temperature of the indoor heat exchanger rises above approximately 5°C, the frequency is raised by
approximately 5 Hz once every 60 seconds, and normal operation is restored.
If the temperature of the indoor heat exchanger goes down to approximately 0°C and this condition continues for 4
minutes, the compressor is stopped.
When the temperature rises above approximately 2uC, normal operation is restored.
19
Shopping Cart more
WM-FX890
MDDR470HBL
ZF1210C
AWM 8000-F
AE-X10C
AWM 8083/L
GRDVL108EK
LX-572
CFS 616 FS
GRDV500US
ADN4P
XL-MP8H
AWM 5087
QT-270A
QT-270E
QT272ABK
WM-GX77
WM-GX302
GRD70EK
GCI 4733 W/BR
$132.80
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-XS30B
RD-XS30B
Quick Start

$4.99
Current Parse Time: 0.112 s with 123 queries. Queries took 0.018468