Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP AHX13CR Repair Manual

$7.99

SHARP AHX13CR - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  
The manual also covers models
AHX08CRAHX10CRAYX10CRAYX08CRAUX08CRAYX13CR
AUX13CRAUX10CRAEX10CRAEX08CRAEX13CR

Product Reviews
There are currently no reviews for this product.

Other reviews
James Thorp - 12/28/2006 5 of 5 Stars!
Great original Yamaha manual and no problems at all with the ordering process. Will definitely use this website again and would recommend it to anyone else. James Thorp
oleg volkozub - 09/25/2008 5 of 5 Stars!
Very nice clear manual with specifications, thanks!
Nadia Yakunina - 06/19/2007 5 of 5 Stars!
It was so difficult to find this manual on the internet - thanks a lot for making it so easy and simple. Incredibly handy. AND. It looks you make so many people happy for such small money. Good job!
Glen Meyer - 10/26/2008 3 of 5 Stars!
Very fast service, manual is well scanned and clear, but the Appendix A containing PC Command table and Control codes are missing
francesco mayol - 02/11/2007 5 of 5 Stars!
This is the best site to find what you need.I reccomand all thecnicia n to contact User-Manuals .

Customers who bought this product also purchased
SHARP 115U_OM.pdf Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 14BN14 Service Manual
SHARP 14BN14 Service Manual
SHARP 25AN1 Service Manual
SHARP 25AN1 Service Manual
SHARP 12P17S Service Manual
SHARP 12P17S Service Manual
SHARP 14BN1 Service Manual
SHARP 14BN1 Service Manual
SHARP 14BM CHASSIS Service Manual
SHARP 14BM CHASSIS Service Manual

Click to see text excerpt from the manual
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
2-3 Overcurrent protection
(1) DC overcurrent detection, AC overcurrent detection
To protect against overcurrent due to sudden changes in load, the compressor is stopped if the set value AC :
12.5A) is exceeded in the AC section. In this case, the outdoor fan does not stop, and 170 seconds after operation
is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal
is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-
minutes delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and
cutting the power.
(2) DC overcurrent detection
To protect against overcurrent due to sudden changes in load, the compressor is stopped if the set value DC : 23A)
is exceeded in the DC section. In this case, the outdoor fan does not stop, and 170 seconds after operation is
stopped, another try will be made. Seven retries are allowed. On the eight retry, a complete stop request signal is
sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minutes
delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the
power.
2-4 Compressor protector control
If the temperature of the compressor chamber exceeds 114°C, the compressor is stopped. In this case, the outdoor
fan does not stop, and when the compressor chamber temperature decreases to 100°C three minutes after
operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop
request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this
time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the
plug and cutting the power.
2-5 Power transistor module protector
If the temperature of the heat-sink exceeds 90 °C, the compressor is stopped.
In this case, the outdoor fan does not stop, and when the temperature of the heat-sink decreases to 80 °C 170
seconds after operation is stopped, another try will be made.
Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the
outdoor unit will remain stopped until reset is performed. At this time, the 3-minutes delay for control of the outdoor
unit will not function; therefore, do not cancel by removing the plug and cutting the power.
Also if the temperature of the heat-sink exceeds 100uC, a complete stop request signal is sent to the inddor unit,
and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minutes delay for control of the
outdoor unit will not function ; therefore, do not cancel by removing the plug and cutting the power.
2-6 Power factor module
If a voltage error (over 420V) is detected at power factor module output voltage, 170seconds the compressor is
stopped.
In this case, the outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made.
Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the
outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor
unit will not function; therefore, do not cancel by removing the plug and cutting the power.
2-7 Serial signals
(1) Serial signals consist of all 96-bit signals.
(2) If the outdoor unit does not receive a serial signal, it will stop approximately 30 seconds later. Note that this is true
only of normal operation; in test mode, it does not stop and operation takes place based on the test mode
commands.
2-8 Rotation abnormal detection of compressor rotation
If the position detection cannot be performed during feedback operation of compressor operation, operation of the
compressor stopped.
In this case, the outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made.
Seventh retries are allowed. On the eight retry, a complete stop request signal is sent to the inddor unit, and the
outdoor unit will remain stopped until reset is performed. At this time, the 3-minutes delay for control of the outdoor
unit will not function ; therefore, do not cancel by removing the plug and cutting the power.
24
Shopping Cart more
GRDV3000
$7.99
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-85DTSB
RD-85DTSB
Quick Start

$4.99
Current Parse Time: 0.089 s with 69 queries. Queries took 0.012672