Main Sub Content
codecode
2620Rear edge void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
Code number Rear edge void setting
0Rear edge void allowed
1Rear edge void not allowed
30CE mark conformity control ON/OFF setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
Code numberCE mark application setting
0CE mark application control OFF
1CE mark application control ON
38Cancel of stop at drum life over
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
0Stop at drum life over
1Stop cancel at drum life over
39Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
0No memory
14 Mbyte
26 Mbyte
40Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
00 sec
130 sec
260 sec
390 sec
AL-1551 SIMULATION, TROUBLE CODES 10-6 |