AL-1000/1010
Main codeSub codeContents
247Drum counter clear
(Operation/Procedure)
When the START key is pressed, the drum counter value is reset to 0.
13Scanner counter clear
(Operation/Procedure)
When the START key is pressed, the scanner counter value is reset to 0.
251Main motor operation check
(Operation/Procedure)
When the START key is pressed, the main motor is rotated for 30 sec.
To save toner consumption, the different operations are executed depending on installation of the developing unit.
. When the developing unit is installed, the developing bias, the main charger, and the grid are also outputted.
. When the developing unit is not installed, only the motor is rotated.
* Do not turn on the door open/close switch forcibly to execute this simulation.
10Polygon motor operation check
(Operation/Procedure)
When the START key is pressed, the polygon motor is operated for 30sec.
261Manual paper feed section setting
(Operation/Procedure)
1. When this simulation is executed, the currently set bypass code number is displayed.
2. Enter the code number corresponding to the bypass and press the START key, and the setting will be changed.
Code numberBypass
0Single bypass
1Multi bypass
6Destination setting
(Operation/Procedure)
1. When this simulation is executed, the currently set destination code number is displayed.
2. Enter the code number corresponding to the destination and press the START key, and the setting will be changed.
Code numberDestination
0Inch series
1EX AB series
2Japan AB series
7Machine conditions check
(Operation/Procedure)
When this simulation is executed, the current machine setting is displayed.
CPMCopy quantity display
10cpm10
12cpm12
15cpm15