AR-F151
Main codeSub codeContent
2638Cancel of stop at drum life over
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code numberSetting
0Stop at drum life over
1Stop cancel at drum life over
39Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code numberSetting
0No memory
14 Mbyte
26 Mbyte
40Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code numberSetting
00 sec
130 sec
260 sec
390 sec
42Transfer ON timing control setup
(Operation / Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code numberSetting
0Default (330 msec)
1-40 msec
2-30 msec
3-20 msec
4-10 msec
5Default (330 msec)
6+10 msec
7+20 msec
8+30 msec
9+40 msec
9 - 6 |