AR-287/337
AR-407/507
8 -7ItemCounter
Operation/
PurposeAdjustment/Operation test/checkProcedure
FunctionUsed to check and adjust the operation of the separa-
(Purpose)tion charger voltage and its control circuit.
SectionImage processOthers
(Photoconductor/
Developing/Transfer/
Cleaning)
Operation/The separation charger output voltage in printing the
Procedurefront and the back of paper can be adjusted and
nnnnnnnn : Counter value
checked.
1. Select the print mode wiÂ] keth [y and [?] key.
22 -6
2. Enter the adjustment value with the 10-key pad.
3. Press the [EXECUTE] key.PurposeOperation data output/Check (Display/Print)
The [EXECUTE] key is highlighted, the adjustment value entered in
FunctionUsed to output the list of the setting and adjustment
procedure 2 is set, and the voltage corresponding to the set value is(Purpose)data (simulations, counters).
supplied.
After supplying the voltage for 30 sec, the [EXECUTE] key returns toItemDataAdjust/Setting data
the normal display.Operation/When installing or servicing, execute this simulation to
If the [EXECUTE] key is pressed while the voltage is supplProcied, eduretheprint and store the adjustment values and setting data
voltage output is stopped and the [EXECUTE] key returns to the nor-for use in the next servicing. (Memory trouble, PWB re-
mal display.placement, etc.)
FROMT MODE: Front surface print (with the paper feed tray andIn this case, the print conditions can be set optionally.
manual paper feed tray)1. Select the setup item.
BACK MODE: Back surface print (with duplex paper feed) (The selected item is highlighted.)
(AR-287/337)2. Set the item and conditions with the 10-key pad.
3. Press the [EXECUTE] key to print various data.
A: Paper feed mode
1: Manual paper feed
2: Upper paper feed tray
3: Lower paper feed tray
4: Desk upper paper feed tray
5: Desk middle paper feed tray
6: Desk lower paper feed tray
7: Large capacity paper feed tray
(AR-407)
(AR-507)
26
26 -10
PurposeSetting
FunctionUsed to allow entry of the software key input for the
(Purpose)network scanner.
ItemOperation
Operation/1. After entering the sub code of the simulation, enter
Procedurethe software key in the obtained frame of "NEW."
222. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
22 -1is stored.
PurposeOperation data output/Check (Display/Print)3. Reset with the CA key, and the scanner function is enabled.
FunctionUsed to check the print out count of each section in*Only when SCSI (20 channels/NS1) setup is completed.
(Purpose)each operation mode. If the scanner key input is made without setup, it is rejected.
(Used to check the maintenance timing.)4. Special note
7 - 534/5/2000 |