63 -03
63 -07
PurposeAdjustmentPurposeSetting
Function Used to adjust the CCD color balance (gamma).
(Purpose)Function Used to set the target color balance (gamma) for auto
(Purpose)color balance adjustment. The standard color balance
SectionScanner (Image scanning)(gamma) or an optional color balance (gamma) is set as
ItemPicture qualityColor balancethe service target.
SectionImage process (ICU)
Operation/Set the SIT chart (UKOG-0280FCZZ) on the document
Proceduretable, and press the [EXECUTE] key. The color ItemPicture qualityColor balance
coefficient automatic adjustment pattern reading is Operation/1. In the copy color balance adjustment (manual
started to calculate and display the color coefficient Procedureadjustment) (SIM 46-21) mode, the color patch
data. image (adjustment pattern) is outputted. (This must
The color coefficient data of each color can be displayed be adjusted properly.)
with the color key.2. Press the [SETUP] key.
3. Set the color patch image (adjustment pattern) paper
printed in the copy color balance adjustment (manual
adjustment) (SIM 46-21) mode on the document
table.
4. Press the [EXECUTE] key. The color patch image
(adjustment pattern) is read.
5. Press the REPEAT key and perform procedure 4
again.
6. Press the [OK] key.
63 -05The color balance corresponding to the color patch
PurposeSettingimage (adjustment pattern) printed in the copy color
balance adjustment (manual adjustment) is set as the
Function Used to set the CCD color balance (gamma) default.service target.
(Purpose)
SectionScanner (Image scanning)
ItemPicture qualityColor balance
Operation/1. Press the [EXECUTE] key, and the [YES] and [NO]
Procedurekeys become active.
2. When the [YES] key is pressed, the CCD color
balance value is set to the default.
)
63 -08
PurposeSetting
Function Used to set the target color balance (gamma) for auto
(Purpose)color balance adjustment (SIM 46-24). The service
target is set to the default (standard) color balance
(gamma).
63 -06SectionScanner (Image scanning)
PurposeAdjustment/Operation data output check (display, print)ItemPicture qualityColor balance
Function Used to check the color balance (gamma) check patch. Operation/1. Press the [EXECUTE] key.
(Purpose)Procedure2. Press the [YES] key.
The service target is set to the default (standard) color
SectionImage process (ICU)
ItemPicture qualityColor balancebalance (gamma).
Operation/1. Set the color balance check patch printed with SIM
Procedure46-21 on the document table.
2. Press the [EXECUTE] key, and the reading is started
and the data are displayed on the display.
AR-C260/C260M SIMULATION 9 - 57 |