5) Attach the TEL/LIU PWB.8) Reattach the shielding plate.
Insert the connector of the TEL/LIU PWB to the connector of theFit the pawls of the shielding plate to the main unit and secure the
FAX PWB, fit two spacers to the TEL/LIU PWB, and attach theplate using five screws.
TEL/LIU PWB using two M3 screws with washer.
Spacers
TEL/LIU PWB
Screws
M3 Screws with washer
Shielding plate
Insert the power plug of the copier to the outlet and turn
6) Reattach the left rear cabinet.on the main switch. Then, carry out the following
<1> Pass the speaker harness through the hole of the frame of the fax
expansion PWB and connect it to the connector of the fax PWB.procedure.
9) Clear the image memory.
<2> Fit the pawls of the left rear cabinet to the mounting portions of* If an extended memory (AR-MM9) has been mounted in step 7, be
the main unit. Slide the cabinet toward the front of the main unit tosure to carry out this step.
attach it.If no extended memory has been mounted, this step is not neces-
<3> Secure the left rear cabinet using two screws.sary.
<4> Attach the supplied fax connector cover.
<1> [P], [*], [C], and [*] to enter the simulation mode.
Speaker harness<2> Use the 10-key pad to enter ?66? in the main code entry screenScrews
shown below and press the START key.
Left rear cabinet
<3> Use the 10-key pad to enter ?10? in the sub-code entry screen
shown below.
Fax connector cover
Screw<4> Use the 10-key pad to enter ?1? in the submenu screen shown
Pawlsbelow and press the START key.
<Step for mounting extended memory (AR-MM9)>
If you need not to mount an extended memory, proceed to step 8.
7) Mount an additional memory (AR-MM9)
Insert the additional memory into the socket on the FAX PWB.
<5> The screen shown below is displayed and memory clear opera-
tion is executed to restart the main unit.
AR-FX7 INSTALLATION PROCEDURE 3 - 2 |