[07]SIMULATIONS.fm 26 Mo+ 9Ţ9�9�9a9�9Ţ?9�9âa?�?a?
?e9a(9á9�1
Main Sub
ContentsRemark
codecode
4102Document size detection photo sensor detection level adjustment
When this simulation is executed, the detection level of the OC document size detection sensor is displayed.
(Real time display)
Place white paper of A3 or WLT on the document table and press [OK] key or START key with the OC cover
open.
When [START] key is pressed, "EXEC" is highlighted and the document detection level at that moment is
saved in the EEPROM. (The saved value is used as the reference for the following document size detection
control.)
Execution windowAB seriesInch series
Sim41-2 PD SENSOR
43
OCS54
1[128] 2002[128] 2001
3[128] 2004[128] 20021
5[128] 20032
The values are displayed in the range of 0 - 255.
0 (Black) - 255 (White)
The value in [ ] indicates the adjustment threshold value. "EXEC" is highlighted during execution.
OCSWOriginal cover status
Open: Highlighted
Close: Normal display
1 - 5PD sensor detection level
03Document size detection photo sensor light receiving/detection level check
When this simulation is executed, the light receiving level of the document detection photo sensor is
displayed. (Real time display)
The values in parentheses of sensor 4 and 5 are the threshold values of adjustment at SIM41-04. Since
sensors 1 and 3 are not provide with the threshold value of detection at SIM41-04, "0" is always displayed.
Sim41-3 PD SENSOR
OCS
1[000] 2002[000] 200
3[000] 2004[050] 200
5[050] 200
04Detection level adjustment when the document size is settled (15 degrees - 20 degrees)
Set the OC cover to the document size settled state (15 degrees - 20 degrees), and press [OK] key.
1 Initial window 2 After-execution window
Sim41-4 20 SENSORSim41-4 20 SENSOR
OCS
1[000] 1632[000] 148
3[001] 1674[0C6] 180
PRESS OK KEY EXEC5[197] 179
The detection level under the document size settled state is saved in the EEPROM, and the value is
displayed in [ ].
* The document size settled state means the point when the open/close sensor (OCSW) is switched from
ON (highlighted) to OFF (normal display).
4201Developing counter clear
Used to clear the developing counter. When this simulation is executed, the confirmation window is
displayed to confirm to clear or not. To clear, press [OK] key or [START] key. Not to clear, press [Interruption]
key or [CA] key to exit the simulation mode.
Sim42-1 COUNTER CLR
DEVELOPER COUNTER
CLEAR
ARE YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
AR-M206 M161 SIMULATIONS 7-26 |